ELE06-03349
| Rough-In Permanent Service | 11/17/2006 | 11/17/2006 | 11/17/2006 4:27:33 PM | P | DONE |
|
|
Phone #: ###-#### x0960 Internet Inspection Request from: Tracy Robertson was done 11-01-06
|
ELE06-03164
| Final | 11/16/2006 | 11/17/2006 | 11/17/2006 4:19:28 PM | A | PASS |
|
|
rhonda ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith ok no card
|
ELE06-03560
| Final | 11/14/2006 | 11/17/2006 | 11/17/2006 4:19:02 PM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 11/14/2006 at 12:03:06 PM. Contact: ###-####. ok
|
ELE06-04303
| Electrical Rough-In | 11/16/2006 | 11/17/2006 | 11/17/2006 3:19:58 PM | A | PART |
|
|
Scheduled by a contractor via Hello! on 11/16/2006 at 7:06:17 PM. Contact: ###-####. walls ok
|
ELE06-04304
| Electrical Rough-In | 11/16/2006 | 11/17/2006 | 11/17/2006 3:19:37 PM | A | PART |
|
|
Scheduled by a contractor via Hello! on 11/16/2006 at 7:04:24 PM. Contact: ###-####. walls ok
|
ELE06-03637
| Final | 11/17/2006 | 11/17/2006 | 11/17/2006 3:19:14 PM | P | CANC |
|
|
Phone #: ###-#### Internet Inspection Request from: ERIC CENTERS needs final for shell core bld before ele can be finaled called
|
ELE06-02599
| Final | 11/17/2006 | 11/17/2006 | 11/17/2006 2:13:41 PM | P | FAIL |
|
|
Phone #: ###-#### Internet Inspection Request from: Dan Rohl 210.52 (C)(1) shall provide proper spacing for counter top in din rm, 110.3(B) manufactures instruction 15 amp circuits for each jtub system, wall heater not allowed in wet location and does not meet manufactures clearence rquirements called
|
ELE06-04305
| Temporary Service | 11/17/2006 | 11/17/2006 | 11/17/2006 1:13:18 PM | P | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Danette Brookshire t/s u/g new ok, called left message needs conn for GEC and clean dir from t/s
|
ELE06-04227
| Electrical Rough-In | 11/17/2006 | 11/17/2006 | 11/17/2006 1:12:12 PM | P | FAIL |
|
|
Mike; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt corr. called 210.11(C)(2)&52(F) all recepts in laundry shall be on laundry circuit, 314.16 box fill , 300.4 nail plates and 11/4", 110.12(A) relace all plastic boxes with extra KOs broken out, cables sheath shall extent into box 1/4"314.20 boxes not flush furred out wall, 300.14 6" free length
|
ELE06-03724
| Electrical Rough-In | 11/17/2006 | 11/17/2006 | 11/17/2006 12:25:32 PM | P | FAIL |
|
|
###-#### corr. met owner, 300.4(A)(1)&(D) nail plates and 11/4" for holes and cables, 314.20 outside boxes shall be flush with siding, 210.52(A) outlet fixed panel of sliding door wall space, 110.3(B) wire jtub per manufactures instructions, 210.11(C)(3)&52(D) 20 amp bath circuit and location for outlet bathrm, strip sheath from romex and makeup of boxes 6" free lenght, staple cables within 8" ok boxes
|
ELE06-04149
| Permanent Service | 11/17/2006 | 11/17/2006 | 11/17/2006 11:51:42 AM | P | PASS |
|
|
roy; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles p/s u/g rec. ok
|
ELE06-04149
| Final | 11/17/2006 | 11/17/2006 | 11/17/2006 11:51:22 AM | P | PASS |
|
|
roy; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ok
|
ELE06-04305
| Temporary Service | 11/16/2006 | 11/17/2006 | 11/17/2006 11:19:30 AM | A | CANC |
|
|
Scheduled by a contractor via Hello! on 11/16/2006 at 4:07:30 PM. Contact: ###-####.
|
ELE06-04307
| Electrical Rough-In | 11/16/2006 | 11/17/2006 | 11/17/2006 8:44:33 AM | A | PART |
|
|
ceiling cover rough-in, please contact Toby, thank you; Phone #: ###-#### Internet Inspection Request from: Wendy Waters
ceiling and walls front half of store
|
ELE06-03724
| Electrical Rough-In | 11/16/2006 | 11/17/2006 | 11/17/2006 8:43:44 AM | A | FAIL |
|
|
after 9am please//Billie ###-#### metr owner will post correction
|
ELE06-03349
| Final | 11/17/2006 | 11/17/2006 | 11/17/2006 7:51:17 AM | P | CANC |
|
|
Thank You!!; Phone #: ###-#### Internet Inspection Request from: Tracy Robertson Inspection cancelled from web by: Tracy Robertson
|
ELE06-04279
| Electrical Rough-In | 11/16/2006 | 11/17/2006 | 11/16/2006 3:52:24 PM | A | PASS |
|
|
###-#### - mike ok called shall not use screws in plastic box outside 2 gang
|