Inspections for the day of: Friday, November 18, 2011.
Number of inspections: 10
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE07-04012 ELE-Request for Extension11/18/201111/18/201111/18/2011 2:43:33 PMPPASS
said he talked to you over the phone ok to extend, construction on-going
ELE11-02601 Electrical Rough-In11/18/201111/18/201111/18/2011 2:41:16 PMPPASS
Please final this job per our conversation. Thanks! Phone #: ###-#### >> Inspection requested via web by Kevin Perez corrections made, ri ok, called to tell must call for final after all work done
ELE11-01866 Final11/18/201111/18/201111/18/2011 2:40:11 PMPFAIL
Garage Code 9981 Phone #: ###-#### >> Inspection requested via web by Therrin Robertson called, left correction notice, NEC 352.30(A) shall strap riser, 410.16(C)(3) luminaire shall be 6" from shelf, 210.52(A)(2)(3) shall provide outlet in wall space in bar type counter
ELE11-00652 Electrical Rough-In11/18/201111/18/201111/18/2011 2:00:25 PMPPASS
pool trench inspection Mike Brown ###-#### Phone #: ###-#### >> Inspection requested via web by mike brown ok cover u/g for pool area
ELE11-02606 Electrical Rough-In11/18/201111/18/201111/18/2011 1:37:20 PMPPASS
>> Inspection requested via web by Terry Scott ri ok
ELE11-02572 Temporary Service11/17/201111/18/201111/18/2011 10:22:31 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Alan Lusk t/s u/g n ok
ELE11-01131 Final11/17/201111/18/201111/18/2011 9:52:01 AMAPASS
please call upon completion Phone #: ###-#### >> Inspection requested via web by jason ewals met owner, ok final permit, further work will be permitted separately
ELE11-02291 Final11/18/201111/18/201111/18/2011 9:39:00 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Phil Baker ok final
ELE11-02601 Electrical Rough-In11/17/201111/18/201111/18/2011 8:46:47 AMAFAIL
We are ready for a rough-in inspection. Please call Jim with any questions ###-####. Have a nice day!! Phone #: ###-#### >> Inspection requested via web by Kevin Perez called, left message, left correction notice, NEC 334.30 shall staple nm within 12" of box, BCC shall not install devices for ri, shall utilize ground screws for ri inspection
ELE11-02602 Final11/17/201111/18/201111/18/2011 8:20:23 AMAFAIL
this inspection is for a requested inspection on the service for idaho power co hook up Phone #: ###-#### >> Inspection requested via web by Dan Hobdey called, left correction notice, NEC 230.28 only power service drop conductors shall be permitted to be attached to mast,312.5 shall provide abrasion protection for all conductors at panel, 358.30 shall provide secure fastening of riser within 3' of termination (guy kit), 250.52(A) shall use metal water pipe within 5' of entering buildig as ground electrode, NOTE: shall call for p/s inspection