ELE07-04012
| ELE-Request for Extension | 11/18/2011 | 11/18/2011 | 11/18/2011 2:43:33 PM | P | PASS |
|
|
said he talked to you over the phone ok to extend, construction on-going
|
ELE11-02601
| Electrical Rough-In | 11/18/2011 | 11/18/2011 | 11/18/2011 2:41:16 PM | P | PASS |
|
|
Please final this job per our conversation. Thanks! Phone #: ###-#### >> Inspection requested via web by Kevin Perez corrections made, ri ok, called to tell must call for final after all work done
|
ELE11-01866
| Final | 11/18/2011 | 11/18/2011 | 11/18/2011 2:40:11 PM | P | FAIL |
|
|
Garage Code 9981 Phone #: ###-#### >> Inspection requested via web by Therrin Robertson called, left correction notice, NEC 352.30(A) shall strap riser, 410.16(C)(3) luminaire shall be 6" from shelf, 210.52(A)(2)(3) shall provide outlet in wall space in bar type counter
|
ELE11-00652
| Electrical Rough-In | 11/18/2011 | 11/18/2011 | 11/18/2011 2:00:25 PM | P | PASS |
|
|
pool trench inspection Mike Brown ###-#### Phone #: ###-#### >> Inspection requested via web by mike brown ok cover u/g for pool area
|
ELE11-02606
| Electrical Rough-In | 11/18/2011 | 11/18/2011 | 11/18/2011 1:37:20 PM | P | PASS |
|
|
>> Inspection requested via web by Terry Scott ri ok
|
ELE11-02572
| Temporary Service | 11/17/2011 | 11/18/2011 | 11/18/2011 10:22:31 AM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Alan Lusk t/s u/g n ok
|
ELE11-01131
| Final | 11/17/2011 | 11/18/2011 | 11/18/2011 9:52:01 AM | A | PASS |
|
|
please call upon completion Phone #: ###-#### >> Inspection requested via web by jason ewals met owner, ok final permit, further work will be permitted separately
|
ELE11-02291
| Final | 11/18/2011 | 11/18/2011 | 11/18/2011 9:39:00 AM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Phil Baker ok final
|
ELE11-02601
| Electrical Rough-In | 11/17/2011 | 11/18/2011 | 11/18/2011 8:46:47 AM | A | FAIL |
|
|
We are ready for a rough-in inspection. Please call Jim with any questions ###-####. Have a nice day!! Phone #: ###-#### >> Inspection requested via web by Kevin Perez called, left message, left correction notice, NEC 334.30 shall staple nm within 12" of box, BCC shall not install devices for ri, shall utilize ground screws for ri inspection
|
ELE11-02602
| Final | 11/17/2011 | 11/18/2011 | 11/18/2011 8:20:23 AM | A | FAIL |
|
|
this inspection is for a requested inspection on the service for idaho power co hook up Phone #: ###-#### >> Inspection requested via web by Dan Hobdey called, left correction notice, NEC 230.28 only power service drop conductors shall be permitted to be attached to mast,312.5 shall provide abrasion protection for all conductors at panel, 358.30 shall provide secure fastening of riser within 3' of termination (guy kit), 250.52(A) shall use metal water pipe within 5' of entering buildig as ground electrode, NOTE: shall call for p/s inspection
|