ELE13-00109
| ELE-Aging Inspection | 11/18/2014 | 11/18/2014 | 11/18/2014 2:48:56 PM | | DONE |
|
|
Still under construction
|
ELE13-00102
| Final | 11/18/2014 | 11/18/2014 | 11/18/2014 2:43:09 PM | P | PASS |
|
|
UL Listing and disconnecting means confirmed. Final ok
|
ELE12-02275
| ELE-Aging Inspection | 11/18/2014 | 11/18/2014 | 11/18/2014 2:22:46 PM | | DONE |
|
|
Still under construction
|
ELE14-02582
| Rough-In Permanent Service | 11/18/2014 | 11/18/2014 | 11/18/2014 2:18:29 PM | P | PASS |
|
|
Please contact Gary ###-#### with any questions. Phone #: ###-#### Inspection requested via web by Tracy Robertson Rough in ok cover p/s u/g n ok
|
GCE13-00136
| GCE-Final | 11/18/2014 | 11/18/2014 | 11/18/2014 1:29:44 PM | P | PASS |
|
|
Zaman Amani ###-#### Final ok
|
GCE14-00190
| GCE-Permanent Service | 11/18/2014 | 11/18/2014 | 11/18/2014 1:14:57 PM | P | FAIL |
|
|
Greg ###-#### - start service 110.12(B)- There shall be no damaged parts that may affect the mechanical strength of equiptment. TA on overhead broke. 300.4(G)- Where #4 or larger conductors are installed, conduit shall have bushing.
|
ELE14-03166
| Electrical Rough-In | 11/17/2014 | 11/18/2014 | 11/18/2014 12:14:20 PM | P | PART |
|
|
Ceiling rough-in Phone #: ###-#### Inspection requested via web by Celinda Winters Ceiling ok to insulate above grid level
|
ELE14-02476
| Final | 11/17/2014 | 11/18/2014 | 11/18/2014 11:22:02 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by cory carman No card posted. Final ok
|
ELE14-03194
| Permanent Service | 11/17/2014 | 11/18/2014 | 11/18/2014 11:05:56 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by jamie berg p/s u/g rec ok
|
ELE14-03165
| Permanent Service | 11/17/2014 | 11/18/2014 | 11/18/2014 10:38:36 AM | A | PASS |
|
|
Please call Lynn Proctor at ###-#### if you have any questions, comments or concerns. Phone #: ###-#### Inspection requested via web by Lynn Proctor Will check an additional grounding electrode on future rough in due to concrete encased connection outside wall in dirt below service. p/s u/g n ok
|
ELE14-03133
| Conference | 11/17/2014 | 11/18/2014 | 11/18/2014 9:47:23 AM | A | DONE |
|
|
Brad Phone #: ###-#### Discussed if service had rating to add additional circuits if wanted. 20/40 ITE 200 amp with room to twin or quad
|
ELE14-02854
| Final | 11/17/2014 | 11/18/2014 | 11/18/2014 9:13:11 AM | A | PASS |
|
|
Ken// all primary power by others Phone #: ###-#### Sign UL listing and disconnecting means confirmed Final ok
|
ELE14-03197
| Permanent Service | 11/18/2014 | 11/18/2014 | 11/18/2014 8:50:49 AM | P | PASS |
|
|
Please contact Jeremiah Goins at ###-####. Early am requested if available. Phone #: ###-#### Inspection requested via web by Deb Gooden p/s o/h rec ok
|
ELE14-03197
| Final | 11/18/2014 | 11/18/2014 | 11/18/2014 8:50:35 AM | P | PASS |
|
|
Please contact Jeremiah Goins at ###-####. Early am requested if available. Phone #: ###-#### Inspection requested via web by Deb Gooden Service rec final ok
|
ELE12-02903
| ELE-Aging Inspection | 11/18/2014 | 11/18/2014 | 11/18/2014 8:19:08 AM | | DONE |
|
|
Still under construction
|