Inspections for the day of: Wednesday, November 18, 2015.
Number of inspections: 19
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE13-00091 ELE-Aging Inspection11/18/201511/18/201511/18/2015 2:57:17 PM DONE
Still under construction
ELE13-00084 ELE-Aging Inspection11/18/201511/18/201511/18/2015 2:43:52 PM DONE
Still under construction
ELE12-00936 ELE-Aging Inspection11/18/201511/18/201511/18/2015 2:30:43 PM DONE
Still under construction
ELE13-00104 ELE-Aging Inspection11/18/201511/18/201511/18/2015 2:29:55 PM DONE
Waiting on contractor
ELE15-03634 Final11/17/201511/18/201511/18/2015 2:29:18 PMPPASS
Phone #: ###-#### Inspection requested via web by Kyle Lott Final ok
ELE15-01928 Electrical Rough-In11/17/201511/18/201511/18/2015 1:46:03 PMPPASS
Ceiling inspection please. Thanks Phone #: ###-#### Inspection requested via web by Scott Campbell Dining area only grid rough in ok cover
ELE15-02974 Final11/18/201511/18/201511/18/2015 1:25:34 PMPFAIL
Phone #: ###-#### Inspection requested via web by Brad Girard
110.3- Receptacle shall be wired to manufacturers instructions. Open ground in master bed. '
342.30- IMC overhead service riser shall be secured with in 3' of meter base.
406.12- All receptacle outlets installed in a residence shall be tamper resistant type. Garage GFI
ELE15-03484 Electrical Rough-In11/18/201511/18/201511/18/2015 12:57:49 PMPPASS
Greg Phone #: ###-#### Enclosed patio rough in ok cover
ELE15-02922 Final11/18/201511/18/201511/18/2015 12:25:35 PMPFAIL
Habitat for Humanity, Contact Damonn Phone #: ###-#### Inspection requested via web by Cathy Duchek AC, Furnace, transformer not complete.
406.12- All receptacle outlets installed in a residence shall be tamper resistant. All GFCI receptacles.
ELE15-03752 Electrical Rough-In11/18/201511/18/201511/18/2015 11:44:17 AMPPASS
Phone #: ###-#### Inspection requested via web by JENNY EMEL In wall electrical south wall rough in ok cover
ELE15-03736 Electrical Rough-In11/17/201511/18/201511/18/2015 11:43:17 AMAPASS
underground; Rocky Phone #: ###-#### Garage and concrete encased electrode rough in ok cover
ELE15-03752 Electrical Rough-In11/18/201511/18/201511/18/2015 11:21:56 AMPPASS
Electrical in stem wouth stem wall rough in ok cover
ELE15-03728 Temporary Service11/17/201511/18/201511/18/2015 11:19:01 AMAPASS
Phone #: ###-#### Inspection requested via web by Therrin Robertson t/s u/g n ok
ELE15-03368 Electrical Rough-In11/17/201511/18/201511/18/2015 10:39:44 AMACANC
Brandon Phone #: ###-#### Dupicate request see ri/ps
ELE15-03368 Rough-In Permanent Service11/17/201511/18/201511/18/2015 10:38:55 AMAPASS
Brandon Phone #: ###-#### Rough in ok cover p/s u/g n ok
ELE15-02985 Final11/17/201511/18/201511/18/2015 9:55:18 AMAPASS
Mark Phone #: ###-#### Final ok
ELE15-03725 Rough-In Permanent Service11/17/201511/18/201511/18/2015 9:34:08 AMAPASS
Phone #: ###-#### Inspection requested via web by Darryn Coburn Rough in ok cover p/s u/g n ok
ELE15-03024 Final11/17/201511/18/201511/18/2015 9:08:16 AMAFAIL
Phone #: ###-#### Inspection requested via web by daniel bibikov
406.9- Receptacle outlets installed in damp or wet locations shall be weather resistant type. 201, 202 balconies
760.41(B)- Fire alarm circuit disconnecting means shall be isentified in red.
ELE15-03737 Electrical Rough-In11/17/201511/18/201511/17/2015 3:54:09 PMAPASS
Phone #: ###-#### Inspection requested via web by Jessica Powell Small wall rough in ok cover