ELE13-00091
| ELE-Aging Inspection | 11/18/2015 | 11/18/2015 | 11/18/2015 2:57:17 PM | | DONE |
|
|
Still under construction
|
ELE13-00084
| ELE-Aging Inspection | 11/18/2015 | 11/18/2015 | 11/18/2015 2:43:52 PM | | DONE |
|
|
Still under construction
|
ELE12-00936
| ELE-Aging Inspection | 11/18/2015 | 11/18/2015 | 11/18/2015 2:30:43 PM | | DONE |
|
|
Still under construction
|
ELE13-00104
| ELE-Aging Inspection | 11/18/2015 | 11/18/2015 | 11/18/2015 2:29:55 PM | | DONE |
|
|
Waiting on contractor
|
ELE15-03634
| Final | 11/17/2015 | 11/18/2015 | 11/18/2015 2:29:18 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Kyle Lott Final ok
|
ELE15-01928
| Electrical Rough-In | 11/17/2015 | 11/18/2015 | 11/18/2015 1:46:03 PM | P | PASS |
|
|
Ceiling inspection please. Thanks Phone #: ###-#### Inspection requested via web by Scott Campbell Dining area only grid rough in ok cover
|
ELE15-02974
| Final | 11/18/2015 | 11/18/2015 | 11/18/2015 1:25:34 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Brad Girard 110.3- Receptacle shall be wired to manufacturers instructions. Open ground in master bed. ' 342.30- IMC overhead service riser shall be secured with in 3' of meter base. 406.12- All receptacle outlets installed in a residence shall be tamper resistant type. Garage GFI
|
ELE15-03484
| Electrical Rough-In | 11/18/2015 | 11/18/2015 | 11/18/2015 12:57:49 PM | P | PASS |
|
|
Greg Phone #: ###-#### Enclosed patio rough in ok cover
|
ELE15-02922
| Final | 11/18/2015 | 11/18/2015 | 11/18/2015 12:25:35 PM | P | FAIL |
|
|
Habitat for Humanity, Contact Damonn Phone #: ###-#### Inspection requested via web by Cathy Duchek AC, Furnace, transformer not complete. 406.12- All receptacle outlets installed in a residence shall be tamper resistant. All GFCI receptacles.
|
ELE15-03752
| Electrical Rough-In | 11/18/2015 | 11/18/2015 | 11/18/2015 11:44:17 AM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by JENNY EMEL In wall electrical south wall rough in ok cover
|
ELE15-03736
| Electrical Rough-In | 11/17/2015 | 11/18/2015 | 11/18/2015 11:43:17 AM | A | PASS |
|
|
underground; Rocky Phone #: ###-#### Garage and concrete encased electrode rough in ok cover
|
ELE15-03752
| Electrical Rough-In | 11/18/2015 | 11/18/2015 | 11/18/2015 11:21:56 AM | P | PASS |
|
|
Electrical in stem wouth stem wall rough in ok cover
|
ELE15-03728
| Temporary Service | 11/17/2015 | 11/18/2015 | 11/18/2015 11:19:01 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Therrin Robertson t/s u/g n ok
|
ELE15-03368
| Electrical Rough-In | 11/17/2015 | 11/18/2015 | 11/18/2015 10:39:44 AM | A | CANC |
|
|
Brandon Phone #: ###-#### Dupicate request see ri/ps
|
ELE15-03368
| Rough-In Permanent Service | 11/17/2015 | 11/18/2015 | 11/18/2015 10:38:55 AM | A | PASS |
|
|
Brandon Phone #: ###-#### Rough in ok cover p/s u/g n ok
|
ELE15-02985
| Final | 11/17/2015 | 11/18/2015 | 11/18/2015 9:55:18 AM | A | PASS |
|
|
Mark Phone #: ###-#### Final ok
|
ELE15-03725
| Rough-In Permanent Service | 11/17/2015 | 11/18/2015 | 11/18/2015 9:34:08 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Darryn Coburn Rough in ok cover p/s u/g n ok
|
ELE15-03024
| Final | 11/17/2015 | 11/18/2015 | 11/18/2015 9:08:16 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by daniel bibikov 406.9- Receptacle outlets installed in damp or wet locations shall be weather resistant type. 201, 202 balconies 760.41(B)- Fire alarm circuit disconnecting means shall be isentified in red.
|
ELE15-03737
| Electrical Rough-In | 11/17/2015 | 11/18/2015 | 11/17/2015 3:54:09 PM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Jessica Powell Small wall rough in ok cover
|