Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM15-03932 Plumbing Rough-in11/17/201511/18/201511/18/2015 4:28:13 PMPFAIL
JOB # 18282. Phone #: ###-#### Inspection requested via web by Ann Marie Reyes
>dwv and water test fail
>replace bad water guage, stuck on 80# with no air in pipes.
PLM15-03422 Plumbing Rough-in11/17/201511/18/201511/18/2015 4:08:15 PMPFAIL
JOB # 13391. Phone #: ###-#### Inspection requested via web by Ann Marie Reyes
>water test failed, no air
>replace water test gauge, it is stuck on 20# with no air in pipes
>3" drain in joist's over kitchen is flat or backgraded.
PLM15-03997 Water Heater Final11/18/201511/18/201511/18/2015 3:38:06 PMPPASS
Please call tenant when on the way. Mary ###-####. Thanks Phone #: ###-#### Inspection requested via web by chris thornburg
PLM15-03975 Final11/18/201511/18/201511/18/2015 3:25:31 PMPFAIL
Please inspect after 2 PM and do this one AFTER Permit # PLM15-03959 at 4775 N Edelweiss. Same owner. Phone #: ###-#### Inspection requested via web by Mary LaFayette
>Need an airgap @ softener drain, have tech send me a picture when complete
PLM15-03706 Final11/16/201511/18/201511/18/2015 3:11:09 PMPPASS
Phone #: ###-#### Inspection requested via web by Brent Lacy
PLM15-03959 Final11/18/201511/18/201511/18/2015 3:03:36 PMPPASS
Please inspect after 2 PM and do this one BEFORE Permit # PLM15-03975 at 2875 Caradoc. Same owner. Phone #: ###-#### Inspection requested via web by Mary LaFayette
PLM15-03399 Final11/18/201511/18/201511/18/2015 2:45:37 PMPFAIL
Phone #: ###-#### Inspection requested via web by Aarin Van Curen
>plumbing ok
>sprinkler backflow needs permitted before plumbing will be signed off. superintendent is aware and making phone call to sprinkler contractor.
PLM15-03995 Final11/18/201511/18/201511/18/2015 2:16:39 PMPPASS
Jeff will give you a call when ready for inspection. Phone #: ###-#### Inspection requested via web by James Staley
PLM15-03983 Plumbing Rough-in11/18/201511/18/201511/18/2015 2:00:49 PMPPASS
Phone #: ###-#### Inspection requested via web by Robert Madrigal
>add 3" cleanout at end of line by final
PLM15-03931 Plumbing Rough-in11/17/201511/18/201511/18/2015 1:42:11 PMPCANC
JOB # 18269. Phone #: ###-#### Inspection requested via web by Ann Marie Reyes
>dwv test failed
PLM15-03930 Plumbing Rough-in11/17/201511/18/201511/18/2015 1:41:40 PMPFAIL
JOB # 18268. Phone #: ###-#### Inspection requested via web by Ann Marie Reyes
>dwv and water test fail
PLM15-03231 Final11/17/201511/18/201511/18/2015 1:22:09 PMPNR
Job # 18191 Phone #: ###-#### Inspection requested via web by Ann Marie Reyes
PLM15-02877 Final11/17/201511/18/201511/18/2015 1:21:36 PMPPASS
JOB # 18145. Phone #: ###-#### Inspection requested via web by Ann Marie Reyes
PLM15-03703 Plumbing Rough-in11/17/201511/18/201511/18/2015 12:53:36 PMPPART
Phone #: ###-#### Inspection requested via web by PATTY KIRK
>south west bathroom ri ok
PLM15-03823 Water and/or Sewer11/17/201511/18/201511/18/2015 11:32:41 AMAPASS
check water test on interceptor.
>test ok
PLM15-03916 Water and/or Sewer11/17/201511/18/201511/18/2015 11:13:14 AMAPART
Please call Brian Anderson with questions ###-#### Thank you, Phone #: ###-#### Inspection requested via web by Jennifer Alcala
>ok to bury water service when tracer wire is done.
>need to add expansion tank since a DCVA for premise protection was installed.
PLM15-01723 Final11/18/201511/18/201511/18/2015 10:45:58 AMAPASS
lowered service sink as per GC Phone #: ###-#### Inspection requested via web by Raul Castanon
>final ok, could not find sign off card
PLM15-02967 Final11/17/201511/18/201511/18/2015 10:25:52 AMAPASS
JOB # 13316 Phone #: ###-#### Inspection requested via web by Ann Marie Reyes
PLM15-02456 PLM-Aging Inspection11/18/201511/18/201511/18/2015 10:13:28 AM PART
wip
PLM15-01382 PLM-Aging Inspection11/18/201511/18/201511/18/2015 10:08:34 AM PART
wip
PLM15-03983 Plumbing Rough-in11/17/201511/18/201511/18/2015 10:02:29 AMANR
Phone #: ###-#### Inspection requested via web by Robert Madrigal
PLM15-03988 Plumbing Rough-in11/17/201511/18/201511/18/2015 9:43:02 AMAFAIL
Phone #: ###-#### Inspection requested via web by Ryan Baker
>DWV test failed, leaks in crawl
PLM15-03569 Final11/17/201511/18/201511/18/2015 9:29:21 AMAFAIL
Phone #: ###-#### Inspection requested via web by Tobi Wilson
>need ASSE 1070 approved tempering valve, faucet is not ASSE 1070 approved.
PLM15-02692 Final11/18/201511/18/201511/18/2015 9:19:16 AMAPASS
correction made
PLM15-02849 Final11/17/201511/18/201511/18/2015 9:17:27 AMAPASS
JOB # 18135. Phone #: ###-#### Inspection requested via web by Ann Marie Reyes
PLM15-03987 DOC - Permit Finaled11/18/201511/18/201511/18/2015 9:11:01 AMPPASS
PLM15-03987 Water and/or Sewer11/17/201511/18/201511/18/2015 9:10:31 AMAPASS
Phone #: ###-#### Inspection requested via web by Brett Simmons
PLM15-03978 Water and/or Sewer11/17/201511/18/201511/18/2015 8:52:54 AMAFAIL
Steve Phone #: ###-####
>must have approved plans onsite
>sWhen sewer and water cross, sewer pipe must be sch 40 the entire way. or relocate water to seperate trench.
PLM15-02421 PLM-Aging Inspection11/18/201511/18/201511/18/2015 7:59:17 AM PART
wip