PLM01-03078
| PLM-Aging Inspection | 11/19/2001 | 11/19/2001 | 11/19/2001 12:00:00 AM | | NR |
|
|
no inspection requested 11/19/2001 1:55:25 PM
|
PLM01-01562
| PLM-Aging Inspection | 11/19/2001 | 11/19/2001 | 11/19/2001 12:00:00 AM | | PASS |
|
|
|
PLM01-02469
| Final | 11/16/2001 | 11/19/2001 | 11/19/2001 12:00:00 AM | A | PASS |
|
|
###-#### MICHAEL
|
PLM01-02494
| Final | 11/16/2001 | 11/19/2001 | 11/19/2001 12:00:00 AM | A | PART |
|
|
MARK ###-#### need to pipe roof drain,s on car wash building to out side need to provide secondary roof drainage for car wash building need gas-tight lid,s on car wash intercepter need non-potable water sign,s on hose bib,s on car wash building. air gap all draines to floor sink,s in main building, fasten hose bib,s on main building 11/20/2001 9:18:27 AM
|
PLM01-03935
| Plumbing Rough-in | 11/16/2001 | 11/19/2001 | 11/19/2001 12:00:00 AM | A | FAIL |
|
|
###-#### trap arm for toilet to long, need to support abs piping every 4 feet and need cleanout,s in two and three inch horizontal drain piping. 11/19/2001 11:05:27 AM
|
PLM01-03814
| Water Heater Final | 11/16/2001 | 11/19/2001 | 11/19/2001 12:00:00 AM | P | PASS |
|
|
###-####
|
PLM01-03885
| Plumbing Rough-in | 11/19/2001 | 11/19/2001 | 11/19/2001 12:00:00 AM | P | PASS |
|
|
###-#### ROD
|
PLM01-03482
| Final | 11/19/2001 | 11/19/2001 | 11/19/2001 12:00:00 AM | P | PASS |
|
|
fn dave ###-####
|
PLM00-03411
| Final | 11/19/2001 | 11/19/2001 | 11/19/2001 12:00:00 AM | P | PART |
|
|
###-#### DAREN need to have all blackflow devices tested and certified 11/19/2001 4:32:33 PM
|
PLM01-03641
| Water and/or Sewer | 11/19/2001 | 11/19/2001 | 11/19/2001 12:00:00 AM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 11/19/2001 at 10:26:51. Contact: ###-####. water line only 11/19/2001 3:07:11 PM
|