Inspections for the day of: Tuesday, November 19, 2013.
Number of inspections: 19
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorDaryl DeGrange
TitleELE-INSPECTION SUPV
Phone #794-1379
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE13-03198 Rough-In Permanent Service11/18/201311/19/201311/20/2013 10:16:02 AMPPASS
DEAN IS THE CONTACT ###-####. PLEASE CALL BEOFRE YOU COME OUT SO WE CAN BE CERTAIN TO MEET YOU THERE. MIKE. Phone #: ###-#### >> Inspection requested via web by Mike TenHulzen rough-in p/s u/g rec ok
ELE13-02434 Final11/19/201311/19/201311/20/2013 9:12:52 AMPPASS
call for code to get in Phone #: ###-#### >> Inspection requested via web by Chris Berthelot final ok
ELE13-03060 Electrical Rough-In11/18/201311/19/201311/20/2013 8:55:00 AMPPASS
Phone #: ###-#### >> Inspection requested via web by Stan Woodward rough-in ok cover ceiling grid
ELE13-03145 Final11/19/201311/19/201311/20/2013 8:30:10 AMPPASS
After 2:00 if possible. Please call for access!! Phone #: ###-#### >> Inspection requested via web by Rex Boyles final ok
ELE12-01431 Final11/18/201311/19/201311/20/2013 8:09:27 AMPPASS
Please call Mike Johnson @ ###-#### to schedule access Phone #: ###-#### >> Inspection requested via web by steve ragan ETL listed spa final ok
ELE13-02989 Final11/19/201311/19/201311/19/2013 2:54:17 PMPFAIL
Phone #: ###-#### >> Inspection requested via web by Brad Baker Receptacle shall not be install above ceiling grid
ELE13-03223 Conference11/18/201311/19/201311/19/2013 2:26:55 PMADONE
Pleas call 30min prior for access - Chris Phone #: ###-#### Discussed with homeowner electrical requirements for detached garage with future bonus room. Homeowner will install branch circuits than hire Elect. contractor to install service panel
ELE13-03245 Permanent Service11/18/201311/19/201311/19/2013 1:49:35 PMAPASS
shop is behind address drive way is on the right of the duplex 4103 and 4101 Phone #: ###-#### >> Inspection requested via web by Jay Symonds p/s o/h n ok
ELE13-03071 Final11/19/201311/19/201311/19/2013 1:31:41 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Brad Baker final ok
ELE13-03229 Electrical Rough-In11/18/201311/19/201311/19/2013 1:20:27 PMAPASS
Need an ok to cover new walls. Phone #: ###-#### >> Inspection requested via web by John Edwards rough-in ok cover master bath walls
ELE13-02822 Final11/19/201311/19/201311/19/2013 12:36:47 PMAPASS
the key on the left side of the front door up on a rock ledge, thx. Phone #: ###-#### >> Inspection requested via web by Stephen Kren final ok
ELE13-02955 Permanent Service11/19/201311/19/201311/19/2013 12:15:43 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Kevin Burke p/s u/g rec ok
ELE13-01218 Final11/19/201311/19/201311/19/2013 12:07:26 PMAPASS
Phone #: ###-#### >> Inspection requested via web by Emmet Bushman final ok
ELE13-02717 Electrical Rough-In11/17/201311/19/201311/19/2013 10:12:47 AMAPASS
call 1/2 hr prior to inspection.
mike ###-#### Phone #: ###-#### >> Inspection requested via web by MIKE HAGERTY rough-in ok cover remodel
ELE13-03235 Temporary Service11/18/201311/19/201311/19/2013 9:48:14 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Bob Glenn t/s u/g n ok
ELE13-03234 Electrical Rough-In11/18/201311/19/201311/19/2013 9:41:22 AMAPASS
Roger Phone #: ###-#### rough-in ok cover trench,
GCE13-00195 GCE-Final11/18/201311/19/201311/19/2013 9:15:38 AMANR
Greg ###-#### not ready for final at this time
GCE13-00195 GCE-Rough-In Permanent Service11/19/201311/19/201311/19/2013 9:14:03 AMPPASS
Greg ###-#### mobile home service rough-in p/s u/g n ok
ELE13-03206 Electrical Rough-In11/18/201311/19/201311/19/2013 8:54:23 AMAPASS
Underground cover inspection. Please contact Guy Thomas with any questions ###-#### Phone #: ###-#### >> Inspection requested via web by Clint Tate rough-in ok cover conduits under slab