ELE15-03722
| Final | 11/19/2015 | 11/19/2015 | 11/19/2015 2:55:52 PM | P | FAIL |
|
|
We need to get a final inspection on this project. We have a few irreversible crimps that need to be completed and we are waiting for the proper die which should be delivered to our shop by 10:30 this morning. We should hopefully be ready for an inspection by early afternoon. Please coordinate with Tony ###-####. Thanks, Sean Phone #: ###-#### Inspection requested via web by Kevin Perez 240.15(B)(1)-Multiwire branch circuits shall have handle ties to ensure all ungrounded conductors are turned of all at once. 680.21(C)- Circulating system receptacle 120 through 240 volt shall have GFCI protection.
|
ELE15-03752
| Electrical Rough-In | 11/19/2015 | 11/19/2015 | 11/19/2015 1:58:20 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by JENNY EMEL Under ground to service bays service rough in ok cover
|
ELE15-03753
| Temporary Service | 11/18/2015 | 11/19/2015 | 11/19/2015 1:43:25 PM | P | PASS |
|
|
HP. Phone #: ###-#### Inspection requested via web by Sean DeLacy t/s o/h n ok
|
ELE15-02922
| Final | 11/18/2015 | 11/19/2015 | 11/19/2015 1:24:24 PM | P | FAIL |
|
|
Re-inspection for Habitat for Humanity, Contact Damonn. Phone #: ###-#### Inspection requested via web by Cathy Duchek 210.8- Receptacle outlets serving counter top in kitchen shall have GFCI protection. Unable to test due to trips as soon as load introduced. 350.30- LFMC shall be secured with in 12" of AC disconnect. 410.16- Luminaires located in closets shall have totally enclosed lamps and shall not be located with in 12" of shelves. Under stair and up closet. 440.22(C)- Overcurrent protection device shall ot exceed value on AC name plate. 30amp on 20 amp max
|
ELE15-03130
| Final | 11/18/2015 | 11/19/2015 | 11/19/2015 12:51:15 PM | P | PASS |
|
|
if locked garage code is 1,2,3,4,enter Phone #: ###-#### Inspection requested via web by Richard Gratiot Final ok
|
ELE15-03754
| Temporary Service | 11/18/2015 | 11/19/2015 | 11/19/2015 12:23:05 PM | P | PASS |
|
|
HP Phone #: ###-#### Inspection requested via web by Sean DeLacy t/s o/h n ok
|
ELE15-02582
| Final | 11/18/2015 | 11/19/2015 | 11/19/2015 11:06:25 AM | A | PASS |
|
|
gouse is empty. key is on west side of house under old phone box Phone #: ###-#### Inspection requested via web by Kelly Felin Final ok
|
ELE15-03041
| Final | 11/18/2015 | 11/19/2015 | 11/19/2015 10:32:44 AM | A | PASS |
|
|
Scott. Phone #: ###-#### Inspection requested via web by Sean DeLacy Final ok
|
ELE15-03018
| Final | 11/18/2015 | 11/19/2015 | 11/19/2015 10:05:07 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Andrea Creek Final ok
|
ESC15-01315
| Random Inspection | 11/19/2015 | 11/19/2015 | 11/19/2015 9:49:14 AM | P | PASS |
|
|
Trash contained
|
ESC15-01142
| Random Inspection | 11/19/2015 | 11/19/2015 | 11/19/2015 9:47:44 AM | P | PASS |
|
|
Trash contained
|
ELE15-03715
| Electrical Rough-In | 11/18/2015 | 11/19/2015 | 11/19/2015 9:42:13 AM | A | CANC |
|
|
Phone #: ###-#### Inspection requested via web by David Nelson Duplicate request. See RI/PS
|
ELE15-03715
| Rough-In Permanent Service | 11/18/2015 | 11/19/2015 | 11/19/2015 9:41:24 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by David Nelson rough in ok cover p/s u/g n ok
|
ELE15-03205
| Final | 11/19/2015 | 11/19/2015 | 11/19/2015 9:29:24 AM | A | PASS |
|
|
CODE 1234 Phone #: ###-#### Inspection requested via web by Bob Glenn Final ok
|
ELE15-03242
| Rough-In Permanent Service | 11/19/2015 | 11/19/2015 | 11/19/2015 9:12:38 AM | A | FAIL |
|
|
Please contact Jerry ###-#### with any questions. Phone #: ###-#### Inspection requested via web by Tracy Robertson 300.4- MC cable shall be protected from physical damage where ran through bored hole that does not maintain 1 1/4" from framing surface. 330.30- MC cable shall be secured with in 12" of boxes.
|
ELE15-03712
| Temporary Service | 11/18/2015 | 11/19/2015 | 11/18/2015 2:44:34 PM | A | CANC |
|
|
This is a temporary pole for the new admixture building. Phone #: ###-#### >> Inspection requested via web by Paula Gratiot Inspection cancelled from web by: Paula Gratiot
|
ELE15-03627
| Permanent Service | 11/18/2015 | 11/19/2015 | 11/18/2015 2:07:11 PM | A | PASS |
|
|
Inspection requested via web by Shawna Gates p/s u/g n ok
|
ELE15-03627
| Permanent Service | 11/18/2015 | 11/19/2015 | 11/18/2015 11:52:16 AM | P | CANC |
|
|
>> Inspection requested via web by Shawna Gates Inspection cancelled from web by: Shawna Gates
|