Inspections for the day of: Wednesday, November 2, 2005.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorPat Lass
TitleELE-INSPECTOR
Phone #794-9478
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE05-03728 Electrical Rough-In11/1/200511/2/200511/2/2005 4:10:53 PMPPASS
need reinspection for ceiling cover-suite 102 and ceiling cover for conduit feeding new transformer in basement ceiling.; Phone #: ###-#### Internet Inspection Request from: dennis mcneely
ELE05-02214 Final11/2/200511/2/200511/2/2005 3:35:50 PMPPART
Phone #: ###-#### Internet Inspection Request from: Kathy Briggs
signed T/O misc fixtures not in yet and 2 coolers hardwired in cord
ELE05-03555 Final11/2/200511/2/200511/2/2005 3:34:37 PMPNH
mark; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
ELE05-03471 Permanent Service11/2/200511/2/200511/2/2005 2:46:03 PMPPASS
don; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
P/S O/H R Ok
ELE05-02544 Electrical Rough-In11/1/200511/2/200511/2/2005 2:10:04 PMPPASS
Scheduled by a contractor via Hello! on 11/1/2005 at 10:20:45 PM. Contact: ###-####.
ELE04-03893 Final11/1/200511/2/200511/2/2005 1:56:36 PMPFAIL
Contact: Mark Robinson; Phone #: ###-#### Internet Inspection Request from: Deb McCoy
outlet required for peninsular counter in kitchen.
GFCI protect receps within 6 ft of wet bar and kitchen counter.
grounding of service to house.
install cover opposite entry on wireway under panels.
closet light locations.
switch in front portch weatherproof.
406.4(e) receps face up from counter in dinningroom.
secure romex behind com cabinet.
coverplate to rest on wall surface in dinningroom
ELE05-03830 Electrical Rough-In11/1/200511/2/200511/2/2005 10:49:44 AMAPASS
spencer; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
ELE05-03833 Temporary Service11/1/200511/2/200511/2/2005 10:21:40 AMAPASS
todd; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
T/S U/G Ok
ELE05-03479 Electrical Rough-In11/1/200511/2/200511/2/2005 10:05:50 AMAPART
please contact George, thank you; Phone #: ###-#### Internet Inspection Request from: Wendy Waters
main floor by panel ok
ELE05-03471 Final11/1/200511/2/200511/2/2005 9:13:44 AMANR
Scheduled by a contractor via Hello! on 11/1/2005 at 9:13:39 PM. Contact: ###-####.
this was for a service change.
water pipe electrode not connected yet.
ELE05-03199 Final11/1/200511/2/200511/2/2005 8:42:48 AMAPASS
Phone #: ###-#### Internet Inspection Request from: John Edwards
finaled with survey 406.3 (b)
ELE05-03830 Permanent Service11/2/200511/2/200511/2/2005 12:00:00 AMPPASS
spencer; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
P/S U/G N OK