BLD07-01358
| BLD-Framing/Rough-in | 11/2/2007 | 11/2/2007 | 11/2/2007 4:27:52 PM | P | NR |
|
|
ron; Phone #: ###-#### Internet Inspection Request from: Barbara Stitt. Needs elec. ri insp. first.
|
BLD07-00737
| BLD-Framing/Rough-in | 11/2/2007 | 11/2/2007 | 11/2/2007 2:56:08 PM | P | PASS |
|
|
Please call one half hour before inspection. Phone #: ###-#### Internet Inspection Request from: Darren Gossett
|
BLD07-02691
| BLD-Foundation | 11/2/2007 | 11/2/2007 | 11/2/2007 2:04:27 PM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 11/2/2007 at 6:59:35 AM. Contact: ###-####.
|
BLD07-02338
| BLD-Framing/Rough-in | 11/1/2007 | 11/2/2007 | 11/2/2007 1:53:05 PM | P | PART |
|
|
zymber Phone #: ###-####
|
BLD07-01026
| BLD-Framing/Rough-in | 11/1/2007 | 11/2/2007 | 11/2/2007 12:55:40 PM | A | PASS |
|
|
lance Phone #: ###-####
|
BLD07-01026
| BLD-Energy code compliance | 11/2/2007 | 11/2/2007 | 11/2/2007 12:55:26 PM | P | PASS |
|
|
lance Phone #: ###-####
|
BLD07-01138
| BLD-Energy code compliance | 11/1/2007 | 11/2/2007 | 11/2/2007 12:14:57 PM | A | PASS |
|
|
gary Phone #: ###-####
|
BLD07-01706
| BLD-Framing/Rough-in | 11/1/2007 | 11/2/2007 | 11/2/2007 12:01:58 PM | A | NR |
|
|
blake Phone #: ###-####. redtag from mech.
|
BLD07-01705
| BLD-Wall cover | 11/2/2007 | 11/2/2007 | 11/2/2007 12:01:22 PM | A | PART |
|
|
Scheduled by a contractor via Hello! on 11/2/2007 at 7:10:09 AM. Contact: ###-####. demissing wall above ceiling ok. tis side only.
|
BLD06-01170
| BLD-Footing | 11/1/2007 | 11/2/2007 | 11/2/2007 11:45:45 AM | A | PART |
|
|
clint Phone #: ###-####wip, still tying verts, left message with structural engineer regarding design strength on concrete. Noted to contractor if he wanted to proceed witjout testing, the contractor accepts all responsibilities.
|
BLD06-02950
| BLD-Final | 11/1/2007 | 11/2/2007 | 11/2/2007 11:17:48 AM | A | FAIL |
|
|
tim Phone #: ###-#### Note: please early morning to coordinate with. complete all fire caulking, Provide UL 3hr listed man door, provide 42"min guards at mezz, provide copy of final letter from special insp. agency and letter from engineer of record accepting non-conformances, Install hc sign at restroom at lease space.
|
BLD05-02539
| BLD-Other | 11/1/2007 | 11/2/2007 | 11/2/2007 9:47:12 AM | A | FAIL |
|
|
mike Note: cover on the admin bld Phone #: ###-####. On site to inspect soffitt, noted type 2b const. Contractor has placed non fire rated osb behind soffitt. No combustibles allowed. Did note that plans on site called for osb, but were not the approved set. will reshedule for Monday and have approved set of drawings.
|
BLD07-02773
| BLD-Framing/Rough-in | 11/1/2007 | 11/2/2007 | 11/2/2007 8:48:46 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 11/1/2007 at 5:29:20 PM. Contact: ###-####.
|