ELE17-03661
| Conference | 11/2/2017 | 11/2/2017 | 11/2/2017 2:25:20 PM | P | DONE |
|
|
Call half hour before to meet // Tom Phone #: ###-#### Discussed the rewiring of complete house. Owner stated had a electrician friend who is going to help out with job. Informed owner they are required to do work as per BCC 4-05-16. All walls appear to be cinder block and may not be able to fish wires into walls. Owner to consider surface mounting wiring method for these areas. Rough in inspection will be treated as if house in new with some concideration for blocking issues. Wall spacing for receptacles, 2 small appliance circuits, dedicated 20 amp for bath receptacles, AFCI, GFCI, tamper and weather resistant. Garage not in scope of work.
|
ELE17-00877
| Final | 11/2/2017 | 11/2/2017 | 11/2/2017 1:29:56 PM | P | PASS |
|
|
Garage code is JAYO enter Phone #: ###-#### Inspection requested via web by Zane Robertson Final ok
|
ELE17-01835
| Final | 11/2/2017 | 11/2/2017 | 11/2/2017 1:04:59 PM | P | FAIL |
|
|
Garage code is JAYO enter Phone #: ###-#### Inspection requested via web by Zane Robertson Corrections not complete. Master bath and powder bath receptacles not working and upstairs main bath shall have GFCI protection as per 210.8.
|
ELE15-02892
| Final | 10/27/2017 | 11/2/2017 | 11/2/2017 12:10:16 PM | P | PASS |
|
|
Aging Phone #: ###-#### Inspection requested via web by Steve VanWinkle Final ok
|
ELE15-02892
| Electrical Rough-In | 11/2/2017 | 11/2/2017 | 11/2/2017 12:09:51 PM | P | PASS |
|
|
Aging Phone #: ###-#### Inspection requested via web by Steve VanWinkle Listing confirmed rough in ok
|
ELE15-02830
| Final | 10/27/2017 | 11/2/2017 | 11/2/2017 12:08:50 PM | P | PASS |
|
|
Aging Phone #: ###-#### Inspection requested via web by Steve VanWinkle Final ok
|
ELE15-02830
| Electrical Rough-In | 11/2/2017 | 11/2/2017 | 11/2/2017 12:08:41 PM | P | PASS |
|
|
Aging Phone #: ###-#### Inspection requested via web by Steve VanWinkle Listing and disconnecting means confirmed. Rough in ok
|
ELE17-02034
| Final | 11/1/2017 | 11/2/2017 | 11/2/2017 10:28:44 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by John VanZandt Final ok
|
ELE17-02211
| Electrical Rough-In | 11/1/2017 | 11/2/2017 | 11/2/2017 9:49:24 AM | A | PASS |
|
|
Contact 208 484 0890 Phone #: ###-#### Inspection requested via web by Mark M BMT freezer walls rough in ok cover
|
ELE17-03453
| Final | 11/1/2017 | 11/2/2017 | 11/2/2017 9:09:59 AM | A | PASS |
|
|
012 is the lock box code. Phone #: ###-#### Inspection requested via web by Barbara Szurgot Final ok
|