Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE13-01268 ELE-Aging Inspection11/2/201711/2/201711/3/2017 12:52:32 PM FAIL
A final inspection is required at this time.
ELE13-02587 ELE-Aging Inspection11/2/201711/2/201711/2/2017 1:34:04 PM FAIL
A final inspection is needed.
ELE17-01030 Final11/1/201711/2/201711/2/2017 1:32:52 PMPPASS
Phone #: ###-#### Inspection requested via web by Kevin Koomler Ok final. In SW corner there is a 5' bond jumper off perimeter bond for a possible handrail leading up to upper level where hot tub is. Talked to contractor, he is going to re-coil wire up put beneath landscape rocks.
ELE17-03676 Final11/1/201711/2/201711/2/2017 1:05:01 PMPPASS
Phone #: ###-#### Inspection requested via web by Jon G. Hoene p/s o/h n ok. Talked to contractor, he is going to call for final once power is restored. Needs to trace out circuits for labeling puposes and arc fault brkr.
ELE17-03584 Electrical Rough-In11/2/201711/2/201711/2/2017 12:04:56 PMPPASS
Later is better Phone #: ###-#### Inspection requested via web by William Andrews Ok cover. A majority of living area and kitch were opened up. Beds and bath not opened, just fished new switch legs for lighting.
ELE17-03679 Temporary Service11/1/201711/2/201711/2/2017 10:58:02 AMAPASS
Phone #: ###-#### Inspection requested via web by Greg Idsinga t/s u/g n ok
ELE17-03547 Temporary Service11/1/201711/2/201711/2/2017 10:57:40 AMAPASS
Phone #: ###-#### Inspection requested via web by Greg Idsinga t/s u/g n ok
ELE17-03696 Temporary Service11/1/201711/2/201711/2/2017 10:23:34 AMAPASS
Phone #: ###-#### Inspection requested via web by Rowdy Monroe t/s u/g n ok
ELE17-03704 Temporary Service11/1/201711/2/201711/2/2017 10:06:27 AMAPASS
Phone #: ###-#### Inspection requested via web by Ryan Wilson t/s o/h n ok
ELE17-03624 Final11/1/201711/2/201711/2/2017 10:06:04 AMAPASS
Contact: Jason Noble Phone #: ###-#### Inspection requested via web by Deb Gooden Ok final. Talked to contractor, they are going to install a short piece of unistrut for mast on detached garage. Also, a small pool is going to be installed within 5 ft of underground feeding house. 680.11 allows this as long as the installation is in rigid metal, intermediate metal, or rigid PVC. 680.10 was deleted from previous 2014 code which required wiring not associated with the pool to be atleast 5 ft away. It is now based on 300.5 cover requirements.
ELE17-03399 Final11/1/201711/2/201711/2/2017 9:30:53 AMAPASS
Call Brad 1 hour ahead of time if needed on site..permit docs are outside of home next to the meter inside of large grey box Phone #: ###-#### Inspection requested via web by Christian Kilpatrick Ok final
ELE17-03589 Final11/1/201711/2/201711/2/2017 9:30:17 AMAPASS
Contact: Jason Noble
Phone #: ###-#### Inspection requested via web by Deb Gooden Ok final. Grounds/neutrals seperated in existing panel. Bonding in new service at alley way. Guy kit will be onsite. A new roof is being put on, guy kit will be installed after.
ELE13-02510 ELE-Aging Inspection11/2/201711/2/201711/2/2017 8:47:47 AM FAIL
A final inspection is needed.
ELE15-02690 Final10/27/201711/2/201711/1/2017 1:43:35 PMPPASS
Aging Phone #: ###-#### Inspection requested via web by Steve VanWinkle
ELE17-00620 ELE-Request for Extension11/1/201711/2/201711/1/2017 12:51:30 PMADONE
Robert Phone #: ###-#### Talked to Robert on phone on 11/1/17, extension is approved.