ELE13-01268
| ELE-Aging Inspection | 11/2/2017 | 11/2/2017 | 11/3/2017 12:52:32 PM | | FAIL |
|
|
A final inspection is required at this time.
|
ELE13-02587
| ELE-Aging Inspection | 11/2/2017 | 11/2/2017 | 11/2/2017 1:34:04 PM | | FAIL |
|
|
A final inspection is needed.
|
ELE17-01030
| Final | 11/1/2017 | 11/2/2017 | 11/2/2017 1:32:52 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Kevin Koomler Ok final. In SW corner there is a 5' bond jumper off perimeter bond for a possible handrail leading up to upper level where hot tub is. Talked to contractor, he is going to re-coil wire up put beneath landscape rocks.
|
ELE17-03676
| Final | 11/1/2017 | 11/2/2017 | 11/2/2017 1:05:01 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Jon G. Hoene p/s o/h n ok. Talked to contractor, he is going to call for final once power is restored. Needs to trace out circuits for labeling puposes and arc fault brkr.
|
ELE17-03584
| Electrical Rough-In | 11/2/2017 | 11/2/2017 | 11/2/2017 12:04:56 PM | P | PASS |
|
|
Later is better Phone #: ###-#### Inspection requested via web by William Andrews Ok cover. A majority of living area and kitch were opened up. Beds and bath not opened, just fished new switch legs for lighting.
|
ELE17-03679
| Temporary Service | 11/1/2017 | 11/2/2017 | 11/2/2017 10:58:02 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Greg Idsinga t/s u/g n ok
|
ELE17-03547
| Temporary Service | 11/1/2017 | 11/2/2017 | 11/2/2017 10:57:40 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Greg Idsinga t/s u/g n ok
|
ELE17-03696
| Temporary Service | 11/1/2017 | 11/2/2017 | 11/2/2017 10:23:34 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Rowdy Monroe t/s u/g n ok
|
ELE17-03704
| Temporary Service | 11/1/2017 | 11/2/2017 | 11/2/2017 10:06:27 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Ryan Wilson t/s o/h n ok
|
ELE17-03624
| Final | 11/1/2017 | 11/2/2017 | 11/2/2017 10:06:04 AM | A | PASS |
|
|
Contact: Jason Noble Phone #: ###-#### Inspection requested via web by Deb Gooden Ok final. Talked to contractor, they are going to install a short piece of unistrut for mast on detached garage. Also, a small pool is going to be installed within 5 ft of underground feeding house. 680.11 allows this as long as the installation is in rigid metal, intermediate metal, or rigid PVC. 680.10 was deleted from previous 2014 code which required wiring not associated with the pool to be atleast 5 ft away. It is now based on 300.5 cover requirements.
|
ELE17-03399
| Final | 11/1/2017 | 11/2/2017 | 11/2/2017 9:30:53 AM | A | PASS |
|
|
Call Brad 1 hour ahead of time if needed on site..permit docs are outside of home next to the meter inside of large grey box Phone #: ###-#### Inspection requested via web by Christian Kilpatrick Ok final
|
ELE17-03589
| Final | 11/1/2017 | 11/2/2017 | 11/2/2017 9:30:17 AM | A | PASS |
|
|
Contact: Jason Noble Phone #: ###-#### Inspection requested via web by Deb Gooden Ok final. Grounds/neutrals seperated in existing panel. Bonding in new service at alley way. Guy kit will be onsite. A new roof is being put on, guy kit will be installed after.
|
ELE13-02510
| ELE-Aging Inspection | 11/2/2017 | 11/2/2017 | 11/2/2017 8:47:47 AM | | FAIL |
|
|
A final inspection is needed.
|
ELE15-02690
| Final | 10/27/2017 | 11/2/2017 | 11/1/2017 1:43:35 PM | P | PASS |
|
|
Aging Phone #: ###-#### Inspection requested via web by Steve VanWinkle
|
ELE17-00620
| ELE-Request for Extension | 11/1/2017 | 11/2/2017 | 11/1/2017 12:51:30 PM | A | DONE |
|
|
Robert Phone #: ###-#### Talked to Robert on phone on 11/1/17, extension is approved.
|