Inspections for the day of: Friday, November 2, 2018.
Number of inspections: 19
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Reynolds
TitleMEC INSPECTOR
Phone #208-803-2395
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC18-05127 Pressure Test11/2/201811/2/201811/2/2018 3:53:22 PMPPASS
Inspection requested via web by Brad Knapton
- 20lb gas pressure test ok- need to see a sediment trap after shut off at furnace- need to add duct work in crawl to permit- secondary drain at indoor coil needs a wet switch and need to see primary condensate termination point at final
MEC18-04929 Rough-in11/2/201811/2/201811/2/2018 3:16:30 PMPPASS
lock box: 1976 Phone #: ###-#### Inspection requested via web by Aaron Alandt
-R/I ok- 5lb flue test failed will need to see a retest before final
MEC18-04929 Pressure Test11/2/201811/2/201811/2/2018 3:15:16 PMPPASS
lock box: 1976 Phone #: ###-#### Inspection requested via web by Aaron Alandt
5lb flue test fail need to retest- 20lb gas pressure test ok
MEC17-01386 Rough-in11/2/201811/2/201811/2/2018 2:40:37 PMPPART
Scott Phone #: ###-####- mini split in the laundry room R/I ok- check outdoor unit for level on next R/I
MEC18-05250 Rough-in11/2/201811/2/201811/2/2018 2:08:03 PMPPASS

Phone #: ###-#### Inspection requested via web by Dawn Kalsbeek- line set support ok- exhaust fans sealed- man j ok- R/I ok
MEC18-05258 Rough-in11/1/201811/2/201811/2/2018 1:55:50 PMPPART
first roughin for microwave venting-Call Jack for access at ###-#### when on way. Call Brian Shoecraft at ###-####9 if any questions please. Thanks, Andrea Creek Phone #: ###-#### Inspection requested via web by Andrea Creek
- partial R/I for range vent downstairs, will get full R/I when venting is finished through 2nd floor and out the roof- keep termination 4' off party wall
MEC18-05258 Conference11/1/201811/2/201811/2/2018 1:53:53 PMPDONE
first roughin for microwave venting-Call Jack for access at ###-#### when on way. Call Brian Shoecraft at ###-####9 if any questions please. Thanks, Andrea Creek Phone #: ###-#### Inspection requested via web by Andrea Creek
MEC18-04944 Final11/1/201811/2/201811/2/2018 1:38:53 PMPPASS
Please call Mary Albers prior to inspection. ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette- furnace co ok
MEC18-05266 Pressure Test11/1/201811/2/201811/2/2018 1:11:23 PMPNH
Please call technician Chris Matos prior to arrival at ###-####.
Thank you Phone #: ###-#### Inspection requested via web by Andrea Grigsby- no access to home
MEC18-04507 Final11/2/201811/2/201811/2/2018 1:04:32 PMPPASS
Fireplace & HVAC, call for garage code - Oleg Phone #: ###-####- final ok
MEC18-05247 Rough-in11/1/201811/2/201811/2/2018 10:36:00 AMAPASS
Phone #: ###-#### Inspection requested via web by Dan Otero- fireplace R/I ok
MEC18-05259 Rough-in11/1/201811/2/201811/2/2018 10:18:26 AMACANC
Phone #: ###-#### Inspection requested via web by Frank Marturello
MEC18-05259 Pressure Test11/1/201811/2/201811/2/2018 10:17:59 AMACANC
Shaun: ###-#### Phone #: ###-#### Inspection requested via web by Frank Marturello
MEC18-04929 Pressure Test11/1/201811/2/201811/2/2018 9:46:53 AMPCANC
lock box: 1279 Phone #: ###-#### >> Inspection requested via web by Aaron Alandt Inspection cancelled from web by: Aaron Alandt
MEC18-04929 Rough-in11/1/201811/2/201811/2/2018 9:46:51 AMPCANC
lock box: 1279 Phone #: ###-#### >> Inspection requested via web by Aaron Alandt Inspection cancelled from web by: Aaron Alandt
MEC18-05143 Rough-in11/1/201811/2/201811/2/2018 9:38:56 AMAPASS
Maya Phone #: ###-####- R/I ok- 5lb flue ok- 20lb gas pressure test ok
MEC18-00564 Mec-Aging Inspection11/2/201811/2/201811/2/2018 9:25:50 AM FAIL
inspection needs scheduled
MEC18-05265 Final11/1/201811/2/201811/2/2018 9:25:14 AMACANC
Phone #: ###-#### Inspection requested via web by Joseph Profitt- outdoor unit needs set
MEC18-05265 Rough-in11/2/201811/2/201811/2/2018 9:24:55 AMPPASS
Phone #: ###-#### Inspection requested via web by Joseph Profitt- multi port mini split ok- dryer vent ok- exhaust fans ok- heads are already hung and condensates finished just need to see outdoor unit set and tied in