ELE07-03880
| Temporary Service | 11/20/2007 | 11/20/2007 | 11/20/2007 3:42:44 PM | P | FAIL |
|
|
jeremy Phone #: ###-#### called left message , correction notice posted by Pat not made
|
ELE07-03875
| Electrical Rough-In | 11/20/2007 | 11/20/2007 | 11/20/2007 2:51:36 PM | P | PART |
|
|
They cut out concrete for adding floor boxes in three locations. We are needing the conduits inspected for pouring concrete back in tomorrow. My cell # is ###-#### Phone #: ###-#### Internet Inspection Request from: Jamie Winters u/g ok
|
ELE07-03464
| Final | 11/20/2007 | 11/20/2007 | 11/20/2007 2:05:47 PM | P | FAIL |
|
|
scott Phone #: ###-#### corr not made new one created grd wiremold extension box island, 408.4 be secific called
|
ELE07-03894
| Temporary Service | 11/20/2007 | 11/20/2007 | 11/20/2007 1:23:38 PM | P | FAIL |
|
|
Charles Phone #: ###-#### called corrections 110.3 install GEC in acorn properly, needs conn for GEC, 110.12(C) clean t/s
|
ELE07-03878
| Electrical Rough-In | 11/20/2007 | 11/20/2007 | 11/20/2007 12:39:27 PM | P | PART |
|
|
water treatment plant Phone #: ###-#### Internet Inspection Request from: Celinda Winters r/i ok correction posted for equipment that needs listing bottle washer, filler, ozone equipment
|
ELE07-02756
| Electrical Rough-In | 11/19/2007 | 11/20/2007 | 11/20/2007 11:52:27 AM | A | FAIL |
|
|
Dennis Phone #: ###-#### corr met owner, box fill 11/4" for cables parallel, #4 for GEC, protect cables 6ft attic access, countertop outlet spacing, outside boxes shall be flush with siding, staple cables within 8", note no cutin boxes for new const. , complete makeup
|
ELE07-02324
| Electrical Rough-In | 11/19/2007 | 11/20/2007 | 11/20/2007 11:03:57 AM | A | PART |
|
|
Inspect floor heat in master bath. Phone #: ###-#### Internet Inspection Request from: Barbara Szurgot ok
|
ELE07-03861
| Rough-In Permanent Service | 11/20/2007 | 11/20/2007 | 11/20/2007 10:51:10 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 11/20/2007 at 5:48:45 AM. Contact: ###-####. r/i p/s u/g new ok
|
ELE07-03886
| Rough-In Permanent Service | 11/19/2007 | 11/20/2007 | 11/20/2007 10:16:22 AM | A | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Jarrod Clymer p/s u/g new ok no r/i yet
|
ELE06-04067
| Final | 11/20/2007 | 11/20/2007 | 11/20/2007 10:15:32 AM | A | PASS |
|
|
wall signs ok
|
ELE06-02437
| DOC - Permit Expired | 11/20/2007 | 11/20/2007 | 11/20/2007 10:14:16 AM | A | PASS |
|
|
contractor has not responded back
|
ELE07-03514
| Electrical Rough-In | 11/20/2007 | 11/20/2007 | 11/20/2007 9:18:03 AM | A | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Ron Zimmerman corr. made ok
|
ELE07-03866
| Temporary Service | 11/19/2007 | 11/20/2007 | 11/20/2007 8:55:01 AM | A | PASS |
|
|
nicholas - please call for access Phone #: ###-#### t/s u/g new ok
|
ELE07-03036
| Final | 11/20/2007 | 11/20/2007 | 11/20/2007 8:43:55 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 11/20/2007 at 5:49:54 AM. Contact: ###-####. ok
|