Inspections for the day of: Tuesday, November 20, 2007.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE07-03153 Electrical Rough-In11/19/200711/20/200711/20/2007 4:27:04 PMPPASS
John; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt met owner, ric ok rooms in house only
ELE07-01557 Final11/15/200711/20/200711/20/2007 3:05:56 PMPCANC
chris Phone #: ###-#### see ri
ELE07-01557 Electrical Rough-In11/20/200711/20/200711/20/2007 2:37:19 PMPFAIL
chris Phone #: ###-#### met owner, cjecked for free length of conductor because devices installed, that part ok, but corrections needed are: nec 210.8(A)(1)&(2) garage and bathroom shall have gfci receptacles installed, 210.70(A)(2) shall provide switched lighting outlet at man door, 300.4(A)&(D) edge of bored holes and nm cable shall be 1 1/4" from edge of framing members, 250 and BCC shall tie grounds together in boxes with more than 1 device
ELE07-03405 Final11/19/200711/20/200711/20/2007 2:13:28 PMPPASS
Dustin, please call 30 minutes prior; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt ok to final
ELE07-03789 Permanent Service11/20/200711/20/200711/20/2007 1:08:21 PMPPASS
Dale Phone #: ###-#### p/s u/g rec ok
ELE07-03824 Electrical Rough-In11/14/200711/20/200711/20/2007 12:15:25 PMPNH
electrician is Aaron White Phone #: ###-#### Internet Inspection Request from: Jarrod Clymer called contractor, they were supposed to co-ordinate somebody home
ELE07-03798 Conference11/19/200711/20/200711/20/2007 10:56:27 AMADONE
dave - please call 1/2 hr prior to inspection Phone #: ###-#### talked about taking over homeowners permit that has been given ric, but need to see ceiling since there may be a question, will call for ri in am
ELE07-03888 Conference11/19/200711/20/200711/20/2007 10:38:52 AMADONE
Ronald Please call 15 min before so he can meet you at the job. Phone #: ###-#### talked about service to shop. grounding for concrete encased electrode, make-up, 1 1/4", when to call for inspection
ELE07-03845 Temporary Service11/19/200711/20/200711/20/2007 9:55:11 AMAPASS
Thank you!! Phone #: ###-#### Internet Inspection Request from: Tracy Robertson corrections made, t/s u/g n ok
ELE07-03844 Temporary Service11/19/200711/20/200711/20/2007 9:30:27 AMAPASS
Thanks Jack!! Phone #: ###-#### Internet Inspection Request from: Tracy Robertson corr made, t/s u/g n ok
ELE07-02602 Final11/19/200711/20/200711/20/2007 9:01:37 AMAPASS
bob Phone #: ###-#### met contractor, ok to final
ELE05-00058 Final11/19/200711/20/200711/20/2007 8:41:07 AMAPASS
bob Phone #: ###-#### ok to final, met contractor
ELE07-03889 Temporary Service11/19/200711/20/200711/20/2007 7:54:38 AMAPASS
Jaret ###-#### t/s u/g n ok