ELE09-02269
| Electrical Rough-In | 11/20/2009 | 11/20/2009 | 11/20/2009 3:58:46 PM | P | PASS |
|
|
Bathroom addition. Installed exhaust fan, 2 lights, and outlet. Homeowners will be home. Use front door. Phone #: ###-#### Internet Inspection Request from: Joe Thomas ric ok
|
ELE09-01826
| Electrical Rough-In | 11/20/2009 | 11/20/2009 | 11/20/2009 3:25:28 PM | P | PASS |
|
|
Contact: John Dillon Phone #: ###-#### Internet Inspection Request from: Randy Vail pole bases ok to pour
|
ESC09-00666
| General Inspection | 11/20/2009 | 11/20/2009 | 11/20/2009 3:03:25 PM | P | PASS |
|
|
looked ok
|
ESC09-00181
| General Inspection | 11/20/2009 | 11/20/2009 | 11/20/2009 3:02:54 PM | P | PASS |
|
|
looked ok, did not notice esc signs, heavy equipment working
|
ESC09-00469
| General Inspection | 11/20/2009 | 11/20/2009 | 11/20/2009 3:01:04 PM | P | PASS |
|
|
looked ok
|
ELE09-02104
| Final | 11/20/2009 | 11/20/2009 | 11/20/2009 2:57:08 PM | P | CANC |
|
|
Gary Phone #: ###-#### see ri, wrong type request, no esc this project
|
ELE09-02104
| Electrical Rough-In | 11/20/2009 | 11/20/2009 | 11/20/2009 2:56:05 PM | P | PASS |
|
|
Gary Phone #: ###-#### ok to backfill concrete encased electrode, no esc this project, called contractor to finish and call for ri for shed since he took over job
|
ELE09-02237
| Rough-In Permanent Service | 11/20/2009 | 11/20/2009 | 11/20/2009 1:52:35 PM | P | FAIL |
|
|
ready for inspection Phone #: ###-#### Internet Inspection Request from: gary batten called, gave correction notice 408.4 shall complete circuit directory, 230.2(E) shall provide permanent plaque at service disconnect, also verify that sub-panels are up to code, no esc this project
|
ELE09-02263
| Rough-In Permanent Service | 11/19/2009 | 11/20/2009 | 11/20/2009 12:38:16 PM | A | PASS |
|
|
call first Phone #: ###-#### Internet Inspection Request from: PAT MILLER p/s o/h rec ok, no esc this project
|
ELE09-02168
| Electrical Rough-In | 11/19/2009 | 11/20/2009 | 11/20/2009 12:16:27 PM | A | PASS |
|
|
Gary Phone #: ###-#### corrections made, ric ok, no esc this project
|
ESC07-01465
| Site Final | 11/20/2009 | 11/20/2009 | 11/20/2009 10:23:53 AM | A | PASS |
|
|
no activity, work is done, ok to final
|
ELE09-02145
| Final | 11/19/2009 | 11/20/2009 | 11/20/2009 10:21:44 AM | A | PASS |
|
|
Jesse Phone #: ###-#### called,survey to not run under counter cord thru cabinet, ok to final, no esc this project
|
ELE09-02258
| Electrical Rough-In | 11/20/2009 | 11/20/2009 | 11/20/2009 9:26:18 AM | A | FAIL |
|
|
called, left correction notice, NEC 300.14 shall provide at least 6" free conductor at boxes- garage, 210.52(A)(1) receptacles shall be spaced such that no point is over 6' from an outlet-entry, front left room, upper landing,upper room, 110.12(B) there shall be no broken boxes-master bath, media room, 110.3(B) listed equipment shall be installed per instructions included with listed product-jetted tub, BCC shall add 5 rooms to permit
|
ELE09-02258
| Permanent Service | 11/20/2009 | 11/20/2009 | 11/20/2009 9:04:58 AM | A | PASS |
|
|
p/s u/g n ok
|
ELE09-02258
| Rough-In Permanent Service | 11/19/2009 | 11/20/2009 | 11/20/2009 9:03:19 AM | A | CANC |
|
|
Phone #: ###-#### Internet Inspection Request from: Bob Glenn called, see ri and p/s
|