Inspections for the day of: Friday, November 20, 2009.
Number of inspections: 15
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE09-02269 Electrical Rough-In11/20/200911/20/200911/20/2009 3:58:46 PMPPASS
Bathroom addition. Installed exhaust fan, 2 lights, and outlet. Homeowners will be home. Use front door. Phone #: ###-#### Internet Inspection Request from: Joe Thomas ric ok
ELE09-01826 Electrical Rough-In11/20/200911/20/200911/20/2009 3:25:28 PMPPASS
Contact: John Dillon Phone #: ###-#### Internet Inspection Request from: Randy Vail pole bases ok to pour
ESC09-00666 General Inspection11/20/200911/20/200911/20/2009 3:03:25 PMPPASS
looked ok
ESC09-00181 General Inspection11/20/200911/20/200911/20/2009 3:02:54 PMPPASS
looked ok, did not notice esc signs, heavy equipment working
ESC09-00469 General Inspection11/20/200911/20/200911/20/2009 3:01:04 PMPPASS
looked ok
ELE09-02104 Final11/20/200911/20/200911/20/2009 2:57:08 PMPCANC
Gary Phone #: ###-#### see ri, wrong type request, no esc this project
ELE09-02104 Electrical Rough-In11/20/200911/20/200911/20/2009 2:56:05 PMPPASS
Gary Phone #: ###-#### ok to backfill concrete encased electrode, no esc this project, called contractor to finish and call for ri for shed since he took over job
ELE09-02237 Rough-In Permanent Service11/20/200911/20/200911/20/2009 1:52:35 PMPFAIL
ready for inspection Phone #: ###-#### Internet Inspection Request from: gary batten called, gave correction notice 408.4 shall complete circuit directory, 230.2(E) shall provide permanent plaque at service disconnect, also verify that sub-panels are up to code, no esc this project
ELE09-02263 Rough-In Permanent Service11/19/200911/20/200911/20/2009 12:38:16 PMAPASS
call first Phone #: ###-#### Internet Inspection Request from: PAT MILLER p/s o/h rec ok, no esc this project
ELE09-02168 Electrical Rough-In11/19/200911/20/200911/20/2009 12:16:27 PMAPASS
Gary Phone #: ###-#### corrections made, ric ok, no esc this project
ESC07-01465 Site Final11/20/200911/20/200911/20/2009 10:23:53 AMAPASS
no activity, work is done, ok to final
ELE09-02145 Final11/19/200911/20/200911/20/2009 10:21:44 AMAPASS
Jesse Phone #: ###-#### called,survey to not run under counter cord thru cabinet, ok to final, no esc this project
ELE09-02258 Electrical Rough-In11/20/200911/20/200911/20/2009 9:26:18 AMAFAIL
called, left correction notice, NEC 300.14 shall provide at least 6" free conductor at boxes- garage, 210.52(A)(1) receptacles shall be spaced such that no point is over 6' from an outlet-entry, front left room, upper landing,upper room, 110.12(B) there shall be no broken boxes-master bath, media room, 110.3(B) listed equipment shall be installed per instructions included with listed product-jetted tub, BCC shall add 5 rooms to permit
ELE09-02258 Permanent Service11/20/200911/20/200911/20/2009 9:04:58 AMAPASS
p/s u/g n ok
ELE09-02258 Rough-In Permanent Service11/19/200911/20/200911/20/2009 9:03:19 AMACANC
Phone #: ###-#### Internet Inspection Request from: Bob Glenn called, see ri and p/s