ELE13-03228
| Temporary Service | 11/20/2013 | 11/20/2013 | 11/21/2013 4:51:53 PM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Rowdy Monroe t/s u/g n ok
|
ELE13-02672
| Electrical Rough-In | 11/19/2013 | 11/20/2013 | 11/21/2013 3:52:14 PM | P | PASS |
|
|
SHANE Phone #: ###-#### Detached garage rough in ok cover
|
ELE13-03258
| Conference | 11/19/2013 | 11/20/2013 | 11/20/2013 4:59:23 PM | P | DONE |
|
|
call 20 min ahead of arrival.....please Phone #: ###-#### >> Inspection requested via web by Kevin Burke Discussed service change on multi family building, 100amp to each unit, 4 wire to range and dryer, and removal of knob and tube that maybe in contact with other materials
|
ELE13-02065
| Final | 11/19/2013 | 11/20/2013 | 11/20/2013 4:28:24 PM | A | FAIL |
|
|
Please call Cory prior to going to inspect so I can meet you there at ###-#### Phone #: ###-#### >> Inspection requested via web by cory carman Label furnace disc. upstairs, Light and switch cover N.W. furnace room, media tripped when light turned on, reverse polarity master bed
|
ELE13-03015
| Electrical Rough-In | 11/20/2013 | 11/20/2013 | 11/20/2013 3:12:19 PM | P | PASS |
|
|
Eli Phone #: ###-#### Walls and hard lid rough in ok cover
|
ELE13-02787
| Electrical Rough-In | 11/20/2013 | 11/20/2013 | 11/20/2013 2:33:31 PM | P | PASS |
|
|
Contact: Wes Powell, wall rough-in inspection please Phone #: ###-#### >> Inspection requested via web by Deb Gooden East and south exterior and south in interior as noted on contractors print. Wall rough in ok cover
|
ELE12-01710
| Electrical Rough-In | 11/20/2013 | 11/20/2013 | 11/20/2013 2:31:40 PM | P | PASS |
|
|
Contact: Wes Powell, ceiling inspection please Phone #: ###-#### >> Inspection requested via web by Deb Gooden Floor 3, 4, 5, elevator lobby ceiling rough in ok cover
|
ELE13-03169
| Temporary Service | 11/19/2013 | 11/20/2013 | 11/20/2013 1:45:50 PM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Jim Williams t/s o/h n ok
|
ELE13-03256
| Final | 11/19/2013 | 11/20/2013 | 11/20/2013 1:32:02 PM | P | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by Brad Girard Contractor to reschedule to future date. Thank You
|
ELE13-02630
| Final | 11/20/2013 | 11/20/2013 | 11/20/2013 1:31:15 PM | P | FAIL |
|
|
Phone #: ###-#### >> Inspection requested via web by Lars Johnson 406.9- grounding type receptical outlets installed on non grounded circuit chall be GFCI protected or changed to non grounding type recepticals. 210.8- Up bath GFCI receptical outlet will not trip.
|
ELE13-02989
| Final | 11/20/2013 | 11/20/2013 | 11/20/2013 12:57:45 PM | P | PASS |
|
|
GFI''s have been corrected Phone #: ###-#### >> Inspection requested via web by Brad Baker Final ok
|
ELE13-02810
| Electrical Rough-In | 11/20/2013 | 11/20/2013 | 11/20/2013 12:46:16 PM | P | PASS |
|
|
Ceiling inspect for the restrooms. Contact is Justin Bieker. Phone #: ###-#### >> Inspection requested via web by Richard Montgomery Rough in ok cover
|
ELE13-03007
| Electrical Rough-In | 11/19/2013 | 11/20/2013 | 11/20/2013 12:32:49 PM | A | PASS |
|
|
cover for floor heat-Mike Phone #: ###-#### Floor heat rough in ok cover
|
ELE12-00913
| ELE-Aging Inspection | 11/20/2013 | 11/20/2013 | 11/20/2013 11:46:16 AM | | CANC |
|
|
too busy
|
ELE13-02642
| Electrical Rough-In | 11/19/2013 | 11/20/2013 | 11/20/2013 10:11:54 AM | A | PASS |
|
|
CONTACT: JEREMIAH GOINS - CEILING INSPECTION PLEASE Phone #: ###-#### >> Inspection requested via web by Deb Gooden Ceiling 3rd floor elevator lobby and baths rough in ok cover
|
ELE13-03240
| Electrical Rough-In | 11/20/2013 | 11/20/2013 | 11/20/2013 9:05:58 AM | P | PASS |
|
|
gate code is 1270 Phone #: ###-#### gh in ok cover
|