Inspections for the day of: Friday, November 20, 2015.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE15-00774 Final11/20/201511/20/201511/20/2015 2:47:36 PMPFAIL
I need a partial because the people are moving in... There''s certain things that aren''t done on the exterior.... Phone #: ###-#### Inspection requested via web by JOHN MCCURDY
* All required receptacles and lighting outlets listed in artical 210 ahll be installed and operational for final.
300.15- All cables shall terminate in boxes.
110.3-Bath fan located in shower stall shall have GFCI protection.
210.52- Receptacle outlets shall be located with in 6' of fixed panel on back slider.
Too many items to list.
Unable to test all receptacles due to items have been moved in prior to inspection.
ELE15-03468 Permanent Service11/20/201511/20/201511/20/2015 1:56:11 PMPFAIL
Service inspection only. Contact is Jay Sprik. Phone #: ###-#### Inspection requested via web by Richard Montgomery 110.24-Available fault current shall be posted with value and date calculated prior to permanent service inspection.
300.4(G)- Raceways containing #4 or larger conductors shall have bushings installed to protect conductors from physical damage.
ELE15-01656 Final11/19/201511/20/201511/20/2015 1:22:43 PMAPASS
Jeff Phone #: ###-#### final ok
ELE15-03779 Temporary Service11/20/201511/20/201511/20/2015 12:54:12 PMPPASS
Phone #: ###-#### Inspection requested via web by David Nelson t/s u/g n ok
ELE15-03778 Temporary Service11/20/201511/20/201511/20/2015 12:41:10 PMPPASS
Phone #: ###-#### Inspection requested via web by David Nelson t/s u/g n ok
ELE15-03777 Temporary Service11/20/201511/20/201511/20/2015 12:28:19 PMPFAIL
Phone #: ###-#### Inspection requested via web by David Nelson
250.28- Main bonding jumper shall terminate in the neutral bar.
ELE15-03242 Rough-In Permanent Service11/19/201511/20/201511/20/2015 11:21:55 AMPPASS
Please contact Tracy ###-#### with any questions. Phone #: ###-#### Inspection requested via web by Tracy Robertson Rough in ok cover shell for exterior lighting only p/s u/g n ok house panel
ELE13-01333 ELE-Aging Inspection11/20/201511/20/201511/20/2015 10:47:56 AM DONE
Waiting on contractor
ELE13-01272 ELE-Aging Inspection11/20/201511/20/201511/20/2015 10:24:43 AM DONE
Waiting on contractor to schedule
ELE12-00227 ELE-Aging Inspection11/20/201511/20/201511/20/2015 9:55:45 AM DONE
Waiting on contractor
ELE15-01769 Final11/19/201511/20/201511/20/2015 9:42:03 AMAPASS
Lock box code is 1122 Phone #: ###-#### Inspection requested via web by Eric Schroeder Final ok
ELE15-03437 Permanent Service11/19/201511/20/201511/20/2015 9:08:57 AMAPASS
Phone #: ###-#### Inspection requested via web by Robert Schroder p/s u/g n ok
ELE15-03722 Final11/20/201511/20/201511/20/2015 8:28:56 AMPPASS
Final ok