ELE02-00129
| Final | 11/19/2002 | 11/21/2002 | 11/21/2002 12:00:00 AM | A | PASS |
|
|
###-#### survey posted called line and load grci right of kit. sink 11/21/2002 1:17:01 PM
|
ELE02-01458
| Permanent Service | 11/20/2002 | 11/21/2002 | 11/21/2002 12:00:00 AM | A | PART |
|
|
1st floor r/i-jeremy; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie area A ceilings and 2nd floor rest rooms hard ceilings ok 11/21/2002 2:15:31 PM
|
ELE02-03621
| Temporary Service | 11/20/2002 | 11/21/2002 | 11/21/2002 12:00:00 AM | A | FAIL |
|
|
TIM ; Phone #: ###-#### Internet Inspection Request from: Darla Downs cor. posted called 230.24(B)(1),and 230.28 support t/s pole,250.53(G), 527.6(B)(1) 11/21/2002 10:55:53 AM
|
ELE02-03273
| Electrical Rough-In | 11/20/2002 | 11/21/2002 | 11/21/2002 12:00:00 AM | A | PART |
|
|
MITCH; Phone #: ###-#### Internet Inspection Request from: Darla Downs partial ceiling r/i ok note owner is doing low voltage and it is a mess 11/21/2002 12:10:07 PM
|
ELE02-03208
| Electrical Rough-In | 11/20/2002 | 11/21/2002 | 11/21/2002 12:00:00 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 11/20/2002 at 17:29:58. Contact: ###-####. ok 11/21/2002 11:18:20 AM
|
ELE02-03266
| Final | 11/21/2002 | 11/21/2002 | 11/21/2002 12:00:00 AM | P | FAIL |
|
|
LLOYD ###-#### cor. posted called seal KOs, 330.30 (C) strap MC within 12 inches where required, 314.25 install cover at hvac unit above ceiling 11/21/2002 2:57:40 PM
|
ELE02-03634
| Rough-In Permanent Service | 11/21/2002 | 11/21/2002 | 11/21/2002 12:00:00 AM | P | NR |
|
|
###-#### no p/s or r/i conference ok 11/21/2002 5:56:58 PM
|
ELE02-03636
| Electrical Rough-In | 11/21/2002 | 11/21/2002 | 11/21/2002 12:00:00 AM | P | PASS |
|
|
###-#### or ###-#### ok kit. 11/21/2002 4:52:21 PM
|
ELE02-03173
| Electrical Rough-In | 11/21/2002 | 11/21/2002 | 11/21/2002 12:00:00 AM | P | NH |
|
|
Scheduled by a contractor via Hello! on 11/21/2002 at 09:45:34. Contact: ###-####. notice posted called 11/21/2002 4:52:54 PM
|
ELE02-03586
| Permanent Service | 11/21/2002 | 11/21/2002 | 11/21/2002 12:00:00 AM | P | PASS |
|
|
concrete is poured for ufer ground. Also, need O.K. for permanent service on exterior of house.; Phone #: ###-#### Internet Inspection Request from: Joe Thomas
p/s u/g new ok 11/21/2002 3:49:16 PM
|
ELE02-01889
| Final | 11/19/2002 | 11/21/2002 | 11/21/2002 12:00:00 AM | P | NH |
|
|
Phone #: ###-#### Internet Inspection Request from: Amy Lawson notice posted 11/21/2002 3:29:44 PM
|