MEC02-03446
| Pressure Test | 11/20/2002 | 11/21/2002 | 11/21/2002 12:00:00 AM | A | PASS |
|
|
###-####
|
MEC02-01979
| Final | 11/20/2002 | 11/21/2002 | 11/21/2002 12:00:00 AM | A | PART |
|
|
room 128 only 11/21/2002 6:22:11 PM
|
MEC02-03382
| Rough-in | 11/20/2002 | 11/21/2002 | 11/21/2002 12:00:00 AM | A | PASS |
|
|
out of time
|
MEC02-03382
| Pressure Test | 11/20/2002 | 11/21/2002 | 11/21/2002 12:00:00 AM | A | PASS |
|
|
out of time
|
MEC02-03139
| Final | 11/21/2002 | 11/21/2002 | 11/21/2002 12:00:00 AM | A | NR |
|
|
PLEASE INSPECT AS CLOSE TO 12:00 NOON AS POSSIBLE; Phone #: ###-#### Internet Inspection Request from: Carol Rasmusssen
|
MEC02-03139
| Pressure Test | 11/21/2002 | 11/21/2002 | 11/21/2002 12:00:00 AM | A | NR |
|
|
PLEASE INSPECT AS CLOSE TO 12:00 NOON AS POSSIBLE; Phone #: ###-#### Internet Inspection Request from: Carol Rasmusssen
|
MEC02-02825
| Final | 11/20/2002 | 11/21/2002 | 11/21/2002 12:00:00 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 11/20/2002 at 14:13:31. Contact: ###-####.
|
MEC02-01273
| Final | 11/20/2002 | 11/21/2002 | 11/21/2002 12:00:00 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 11/20/2002 at 15:16:14. Contact: ###-####.
|
MEC02-03279
| Rough-in | 11/20/2002 | 11/21/2002 | 11/21/2002 12:00:00 AM | A | NR |
|
|
not ready, remove tile for inspection 11/21/2002 3:18:32 PM
|
MEC02-01794
| Final | 11/20/2002 | 11/21/2002 | 11/21/2002 12:00:00 AM | A | FAIL |
|
|
###-####
|
MEC02-03421
| Pressure Test | 11/20/2002 | 11/21/2002 | 11/21/2002 12:00:00 AM | A | PART |
|
|
GAS TEST ONLY FOR NOW. SOME GAS PIPING IN TRENCH. holding pressure, left notice ok to cover trench, will need pressure test when piping is completed out of concealed area to equipment room. 11/21/2002 2:08:23 PM
|
MEC02-03438
| Final | 11/20/2002 | 11/21/2002 | 11/21/2002 12:00:00 AM | P | PASS |
|
|
###-#### DEBBIE
|
MEC02-03366
| Conference | 11/19/2002 | 11/21/2002 | 11/21/2002 12:00:00 AM | P | FAIL |
|
|
can not use pvc pipe at water heater pressure relief drain line, use only cpvc or metal pipe 11/21/2002 6:34:35 PM
|
MEC02-02219
| Final | 11/20/2002 | 11/21/2002 | 11/21/2002 12:00:00 AM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 11/20/2002 at 16:55:54. Contact: ###-####.
|
MEC02-03440
| Final | 11/21/2002 | 11/21/2002 | 11/21/2002 12:00:00 AM | P | PASS |
|
|
PLEASE INSPECT AS CLOSE TO 3:00 AS POSSIBLE
THANKS
CAROL; Phone #: ###-#### Internet Inspection Request from: Carol Rasmusssen
|
MEC02-01930
| Final | 11/21/2002 | 11/21/2002 | 11/21/2002 12:00:00 AM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 11/21/2002 at 09:35:53. Contact: ###-####.
|
MEC02-03269
| Rough-in | 11/21/2002 | 11/21/2002 | 11/21/2002 12:00:00 AM | P | FAIL |
|
|
need repair on i joist and repair plbg vent at 2nd floor r.a. chase 11/21/2002 7:26:44 PM
|
MEC02-03372
| Final | 11/21/2002 | 11/21/2002 | 11/21/2002 12:00:00 AM | P | CANC |
|
|
not here, was at classes 11/25/2002 3:28:00 PM
|
MEC02-03279
| Final | 11/21/2002 | 11/21/2002 | 11/21/2002 12:00:00 AM | P | PART |
|
|
northwest corner ok for cover only, look at rest on monday 11/21/2002 5:13:50 PM
|