ELE08-03093
| Rough-In Permanent Service | 11/21/2008 | 11/21/2008 | 11/21/2008 4:00:07 PM | P | CANC |
|
|
Late PM if possible Please Thanks, Dan Phone #: ###-#### Internet Inspection Request from: Dan Rohl see added r/i , and p/s
|
ELE08-03093
| Electrical Rough-In | 11/21/2008 | 11/21/2008 | 11/21/2008 3:59:44 PM | P | FAIL |
|
|
Late PM if possible Please Thanks, Dan Phone #: ###-#### Internet Inspection Request from: Dan Rohl called corr. 110.2, 110.3 (A&B) and BBC 4-05-33 shall provide 16" x 20" access as manufacture's instructions and j-tub shall be listed and so labeled
|
ELE08-03093
| Permanent Service | 11/21/2008 | 11/21/2008 | 11/21/2008 3:57:07 PM | P | PASS |
|
|
Late PM if possible Please Thanks, Dan Phone #: ###-#### Internet Inspection Request from: Dan Rohl p/s u/g new ok
|
ELE08-01693
| Final | 11/20/2008 | 11/21/2008 | 11/21/2008 3:55:56 PM | P | PASS |
|
|
CONTACT: GREG PACK Phone #: ###-#### Internet Inspection Request from: Deb Gooden ok no card
|
ELE08-00296
| Final | 11/21/2008 | 11/21/2008 | 11/21/2008 2:37:19 PM | P | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Karl Paige ok card signed
|
ELE08-02877
| Electrical Rough-In | 11/21/2008 | 11/21/2008 | 11/21/2008 1:03:44 PM | P | PASS |
|
|
tony Phone #: ###-#### ok
|
ELE08-02877
| Rough-In Permanent Service | 11/21/2008 | 11/21/2008 | 11/21/2008 1:03:26 PM | P | PASS |
|
|
tony Phone #: ###-#### r/i p/s u/g new ok
|
ELE07-03503
| Final | 11/20/2008 | 11/21/2008 | 11/21/2008 11:23:09 AM | A | FAIL |
|
|
dustin Phone #: ###-#### Note: please call 1/2 hr prior to inspection corr called 410.8 needs totally enclosed fixture MB closet, 410.4 needs shower trim, 406.3 and BCC needs gfci all replace recepts in kit. for countertops, 406. 4&5 recepts shall tight in boxes and flush with plates
|
ELE08-03083
| Electrical Rough-In | 11/20/2008 | 11/21/2008 | 11/21/2008 11:19:11 AM | A | PART |
|
|
inspect underground conduit to new shed & rough in of new shed. Any questions call George @ ###-#### Phone #: ###-#### Internet Inspection Request from: Andy okRose
|
ELE08-02348
| Final | 11/20/2008 | 11/21/2008 | 11/21/2008 11:18:45 AM | A | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Barbara Szurgot ok
|
ELE08-02866
| Conference | 11/21/2008 | 11/21/2008 | 11/21/2008 9:13:53 AM | A | DONE |
|
|
Scheduled by a contractor via Hello! on 11/21/2008 at 12:59:12 AM. Contact: ###-####. ok note owner cut equip grd wires short
|
ELE08-02866
| Electrical Rough-In | 11/21/2008 | 11/21/2008 | 11/21/2008 9:13:03 AM | A | PART |
|
|
Scheduled by a contractor via Hello! on 11/21/2008 at 12:59:12 AM. Contact: ###-####. outside soffit lights ok
|
ELE08-02036
| Permanent Service | 11/20/2008 | 11/21/2008 | 11/21/2008 8:34:24 AM | A | PASS |
|
|
Inspection for Fire Pump Service. Job contact is Marc Benner. Phone #: ###-#### Internet Inspection Request from: Cyndi Dale Mickey check neutral bus at fire pump p/s p/s u/g new for fire pump service ok
|
ELE08-03079
| Permanent Service | 11/20/2008 | 11/21/2008 | 11/20/2008 3:03:48 PM | A | PASS |
|
|
permanent service and underground Phone #: ###-#### Internet Inspection Request from: Jenni Keller needs to address nipple between p/s and subpanel, also 4 wire , to range and drywe also 4wire pigtails and recepts for range and dryer p/s u/g rec. ok
|