Inspections for the day of: Monday, November 21, 2016.
Number of inspections: 10
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE16-03680 Rough-In Permanent Service11/18/201611/21/201611/21/2016 2:46:01 PMPPASS
200 amp pedestal / underground Phone #: ###-#### Inspection requested via web by jamie berg
Rough in ok cover p/s u/g n ok
ELE16-03787 Rough-In Permanent Service11/18/201611/21/201611/21/2016 2:38:55 PMPPASS
200 amp pedestal / underground Phone #: ###-#### Inspection requested via web by jamie berg
Rough in ok cover p/s u/g n ok
ELE16-03679 Rough-In Permanent Service11/18/201611/21/201611/21/2016 2:38:29 PMPPASS
200 amp pedestal / underground Phone #: ###-#### Inspection requested via web by jamie berg
Rough in ok cover p/s u/g n ok
ELE16-03744 Electrical Rough-In11/18/201611/21/201611/21/2016 2:11:15 PMPPASS
There will be someone there. Any questions please call Jake ###-#### Phone #: ###-#### Inspection requested via web by Clay Morgan
South east room damaged. Rough in ok cover
ELE15-01303 Final11/21/201611/21/201611/21/2016 1:03:20 PMPPASS
Jack// please call ahead Phone #: ###-#### Final ok
ELE16-03772 Electrical Rough-In11/20/201611/21/201611/21/2016 10:15:35 AMAPASS
call first, ###-#### Phone #: ###-#### Inspection requested via web by PAT MILLER
Kitchen and masterbath rough in ok cover
ELE16-03276 Electrical Rough-In11/18/201611/21/201611/21/2016 10:02:40 AMAPASS
Mucho Phone #: ###-####
House complete. Rough in ok cover
ELE16-03276 Permanent Service11/21/201611/21/201611/21/2016 9:39:29 AMPPASS
Mucho Phone #: ###-####
p/s u/g n ok
ELE16-03779 Electrical Rough-In11/18/201611/21/201611/21/2016 9:13:27 AMAFAIL
Need rough in inspection for detached garage. Most wiring done by another contractor and was previously inspected. Phone #: ###-#### Inspection requested via web by Alan Lusk
BLD permit stated south wall shall have no penetrations or openings. 2 receptacle outlets installed. Need removed and surface mount if needed.
250.32(B)- Any installed grounded conductor shall not be connected to equipment grounding conductor or grounding electrode system.
Upstairs wired as if using for other than storage as BLD states.
Second electrical permit exists
ELE16-03062
ELE16-03778 Electrical Rough-In11/18/201611/21/201611/21/2016 8:36:40 AMAPASS
Need approval to cover all soffits. Phone #: ###-#### Inspection requested via web by Alan Lusk
Soffit rough in ok cover