ELE05-04235
| Final | 11/22/2005 | 11/22/2005 | 11/22/2005 4:09:32 PM | P | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Dana Moyer
|
ELE05-03554
| Electrical Rough-In | 11/22/2005 | 11/22/2005 | 11/22/2005 3:21:44 PM | P | PART |
|
|
Scheduled by a contractor via Hello! on 11/22/2005 at 7:43:22 AM. Contact: ###-####. 3 cut-in boxes
|
ELE05-04223
| Electrical Rough-In | 11/22/2005 | 11/22/2005 | 11/22/2005 2:38:50 PM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 11/22/2005 at 10:19:52 AM. Contact: ###-####. R/I Ok with survey250.104 Bonding of Piping Systems and Exposed Structural Steel. (A) Metal Water Piping. The metal water piping system shall be bonded as required in (1), (2), (3), or (4) of this section. Hot Water
Boise city requires concrete encased electrode for service grounding where new foundation is installed.
Concrete-Encased Electrode. An electrode encased by at least 50 mm (2 in.) of concrete, located within and near the bottom of a concrete foundation or footing that is in direct contact with the earth, consisting of at least 6.0 m (20 ft) of bare copper conductor not smaller than 4 AWG. 250.28 Main Bonding Jumper. For a grounded system, an unspliced main bonding jumper shall be used to connect the equipment grounding conductor(s) and the service-disconnect enclosure to the grounded conductor of the system within the enclosure for each service disconnect. 300.4 Protection Against Physical Damage. Where subject to physical damage, conductors shall be adequately protected. 314.43 Nonmetallic Boxes. Provisions for supports or other mounting means for nonmetallic boxes shall be outside of the box.
|
ELE05-03965
| Electrical Rough-In | 11/22/2005 | 11/22/2005 | 11/22/2005 1:59:50 PM | P | PART |
|
|
brad Note: for cover please call 1/2 hr prior; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles walls in phase 1
|
ELE05-04237
| Temporary Service | 11/22/2005 | 11/22/2005 | 11/22/2005 1:43:48 PM | P | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: William Zerfas T/S O/H Ok
|
ELE05-02192
| ELE-Aging Inspection | 11/22/2005 | 11/22/2005 | 11/22/2005 10:30:58 AM | | NR |
|
|
suc
|
ELE05-04219
| Temporary Service | 11/21/2005 | 11/22/2005 | 11/22/2005 10:30:15 AM | A | PASS |
|
|
Entrance off of Tablerock Rd.; Phone #: ###-#### Internet Inspection Request from: Barbara Szurgot T/S U/G Ok
|
ELE05-02110
| ELE-Aging Inspection | 11/22/2005 | 11/22/2005 | 11/22/2005 9:41:11 AM | | NR |
|
|
suc
|
ELE05-02931
| Electrical Rough-In | 11/21/2005 | 11/22/2005 | 11/22/2005 9:40:31 AM | A | PASS |
|
|
CONTACT: NEIL RAMSEY - TEMPORARY OCCUPANCY INSPECTION; Phone #: ###-#### Internet Inspection Request from: Deb McCoy signed T/O 2 pieces of equipment in basement remain, directories, and strapping if mc in basement.
|
ELE05-02975
| Final | 11/21/2005 | 11/22/2005 | 11/22/2005 8:58:17 AM | A | PASS |
|
|
lloyd; Phone #: ###-#### Internet Inspection Request from: Barbara Moore final ok with survey on GFCI protection of receps within 6 Ft of wet bar.
|
ELE05-02111
| ELE-Aging Inspection | 11/22/2005 | 11/22/2005 | 11/22/2005 7:41:39 AM | | NR |
|
|
suc
|