Inspections for the day of: Tuesday, November 22, 2005.
Number of inspections: 11
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorPat Lass
TitleELE-INSPECTOR
Phone #794-9478
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE05-04235 Final11/22/200511/22/200511/22/2005 4:09:32 PMPPASS
Phone #: ###-#### Internet Inspection Request from: Dana Moyer
ELE05-03554 Electrical Rough-In11/22/200511/22/200511/22/2005 3:21:44 PMPPART
Scheduled by a contractor via Hello! on 11/22/2005 at 7:43:22 AM. Contact: ###-####.
3 cut-in boxes
ELE05-04223 Electrical Rough-In11/22/200511/22/200511/22/2005 2:38:50 PMPPASS
Scheduled by a contractor via Hello! on 11/22/2005 at 10:19:52 AM. Contact: ###-####.
R/I Ok with survey250.104 Bonding of Piping Systems and Exposed Structural Steel.
(A) Metal Water Piping. The metal water piping system shall be bonded as required in (1), (2), (3), or (4) of this section. Hot Water

Boise city requires concrete encased electrode for service grounding where new foundation is installed.

Concrete-Encased Electrode. An electrode encased by at least 50 mm (2 in.) of concrete, located within and near the bottom of a concrete foundation or footing that is in direct contact with the earth, consisting of at least 6.0 m (20 ft) of bare copper conductor not smaller than 4 AWG.
250.28 Main Bonding Jumper.
For a grounded system, an unspliced main bonding jumper shall be used to connect the equipment grounding conductor(s) and the service-disconnect enclosure to the grounded conductor of the system within the enclosure for each service disconnect.
300.4 Protection Against Physical Damage.
Where subject to physical damage, conductors shall be adequately protected.
314.43 Nonmetallic Boxes.
Provisions for supports or other mounting means for nonmetallic boxes shall be outside of the box.

ELE05-03965 Electrical Rough-In11/22/200511/22/200511/22/2005 1:59:50 PMPPART
brad Note: for cover please call 1/2 hr prior; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
walls in phase 1
ELE05-04237 Temporary Service11/22/200511/22/200511/22/2005 1:43:48 PMPPASS
Phone #: ###-#### Internet Inspection Request from: William Zerfas
T/S O/H Ok
ELE05-02192 ELE-Aging Inspection11/22/200511/22/200511/22/2005 10:30:58 AM NR
suc
ELE05-04219 Temporary Service11/21/200511/22/200511/22/2005 10:30:15 AMAPASS
Entrance off of Tablerock Rd.; Phone #: ###-#### Internet Inspection Request from: Barbara Szurgot
T/S U/G Ok
ELE05-02110 ELE-Aging Inspection11/22/200511/22/200511/22/2005 9:41:11 AM NR
suc
ELE05-02931 Electrical Rough-In11/21/200511/22/200511/22/2005 9:40:31 AMAPASS
CONTACT: NEIL RAMSEY - TEMPORARY OCCUPANCY INSPECTION; Phone #: ###-#### Internet Inspection Request from: Deb McCoy
signed T/O 2 pieces of equipment in basement remain, directories, and strapping if mc in basement.
ELE05-02975 Final11/21/200511/22/200511/22/2005 8:58:17 AMAPASS
lloyd; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
final ok with survey on GFCI protection of receps within 6 Ft of wet bar.
ELE05-02111 ELE-Aging Inspection11/22/200511/22/200511/22/2005 7:41:39 AM NR
suc