BLD05-01920
| BLD-Framing/Rough-in | 11/21/2005 | 11/22/2005 | 11/22/2005 3:02:45 PM | P | FAIL |
|
|
dennis; Phone #: ###-#### Internet Inspection Request from: Barbara Moore. Install header over openings at fbi bearing and truss bearing as noted on plans. Add additional bracing to gable ends. Complete nailing of hangars on jack trusses and hangars on 4ply in garage. ok to insul.
|
BLD05-01119
| BLD-Final | 11/21/2005 | 11/22/2005 | 11/22/2005 2:26:13 PM | P | CANC |
|
|
Scheduled by a contractor via Hello! on 11/21/2005 at 1:28:45 PM. Contact: ###-####. Needs life/safety.
|
BLD05-02060
| BLD-Conference | 11/21/2005 | 11/22/2005 | 11/22/2005 2:13:30 PM | P | NR |
|
|
Please final Century Landmark monument sign Internet Inspection Request from: Radon . elec. final failed.
|
BLD05-03131
| BLD-Footing | 11/21/2005 | 11/22/2005 | 11/22/2005 2:02:47 PM | P | PART |
|
|
jim; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa
|
BLD05-02776
| BLD-Final | 11/22/2005 | 11/22/2005 | 11/22/2005 1:45:50 PM | P | FAIL |
|
|
mitch; Phone #: ###-#### Internet Inspection Request from: Barbara Moore. Door to backyard, top of thresh hold to ground exceeds the max 7.75 inch rise.
|
BLD05-00957
| BLD-Final | 11/22/2005 | 11/22/2005 | 11/22/2005 1:16:17 PM | P | FAIL |
|
|
Scheduled by a contractor via Hello! on 11/22/2005 at 9:09:01 AM. Contact: ###-####. Item not repaired.
|
BLD05-02942
| BLD-Conference | 11/21/2005 | 11/22/2005 | 11/22/2005 12:25:40 PM | P | PASS |
|
|
Please final all Century 21 wall signs, first ave prop, idaho career, century gold Internet Inspection Request from: Radon Elaina
|
BLD05-02284
| BLD-Foundation | 11/22/2005 | 11/22/2005 | 11/22/2005 12:24:54 PM | P | PART |
|
|
ryan; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
|
BLD05-02283
| BLD-Foundation | 11/22/2005 | 11/22/2005 | 11/22/2005 12:24:36 PM | P | PART |
|
|
ryan; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
|
BLD05-01725
| BLD-Final | 11/22/2005 | 11/22/2005 | 11/22/2005 12:05:47 PM | P | PASS |
|
|
ernie; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
|
BLD05-01568
| BLD-Framing/Rough-in | 11/22/2005 | 11/22/2005 | 11/22/2005 11:57:45 AM | P | FAIL |
|
|
###-#### brandon reed. Provide truss engineering.
|
BLD05-01335
| BLD-Framing/Rough-in | 11/22/2005 | 11/22/2005 | 11/22/2005 11:45:43 AM | P | FAIL |
|
|
mike; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa. All hangars not nailed off (downstairs)
|
BLD05-02640
| BLD-Foundation | 11/22/2005 | 11/22/2005 | 11/22/2005 11:34:32 AM | A | PART |
|
|
Scheduled by a contractor via Hello! on 11/22/2005 at 7:22:18 AM. Contact: ###-####.
|
BLD05-02640
| BLD-Footing | 11/22/2005 | 11/22/2005 | 11/22/2005 11:34:12 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 11/22/2005 at 7:20:48 AM. Contact: ###-####.
|
BLD05-03010
| BLD-Framing/Rough-in | 11/21/2005 | 11/22/2005 | 11/22/2005 11:20:54 AM | A | PASS |
|
|
ceiling insp//alan; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa
|
BLD04-01264
| BLD-Final | 11/21/2005 | 11/22/2005 | 11/22/2005 10:47:59 AM | A | PASS |
|
|
BOB; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
|
BLD05-02095
| BLD-Framing/Rough-in | 11/18/2005 | 11/22/2005 | 11/22/2005 10:20:36 AM | A | PASS |
|
|
bob ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
|
BLD05-01570
| BLD-Framing/Rough-in | 11/21/2005 | 11/22/2005 | 11/22/2005 9:56:51 AM | A | PASS |
|
|
lon; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
|
BLD04-03025
| BLD-Concrete | 11/21/2005 | 11/22/2005 | 11/22/2005 9:15:53 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 11/21/2005 at 3:02:54 PM. Contact: ###-####. 3rd floor decking at corridors. Also inspected reinforcement for pool, which is under a different permit.
|
BLD05-01904
| BLD-Final | 11/21/2005 | 11/22/2005 | 11/22/2005 9:02:40 AM | A | FAIL |
|
|
ron ; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa. guard railing at stair needs to be repaired so as not to let a 4 inch sphere pass at bottom rung.
|
BLD04-01264
| DOC - Permit Finaled | 11/22/2005 | 11/22/2005 | 11/22/2005 12:00:00 AM | P | PASS |
|
|
|
BLD05-01725
| DOC - Permit Finaled | 11/22/2005 | 11/22/2005 | 11/22/2005 12:00:00 AM | P | PASS |
|
|
|
BLD05-02942
| DOC - Permit Finaled | 11/22/2005 | 11/22/2005 | 11/22/2005 12:00:00 AM | P | PASS |
|
|
|