Inspections for the day of: Friday, November 22, 2019.
Number of inspections: 31
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrian Scoles
TitleMEC INSPECTOR
Phone #914-4915
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC19-04022 Final11/22/201911/22/201911/22/2019 3:46:25 PMPPASS
Range hood Phone #: ###-#### Inspection requested via web by Denton Fuehrer- range hood final ok
MEC19-05199 Final11/21/201911/22/201911/22/2019 3:17:13 PMPFAIL
PLEASE CALL HOMEOWNER JESSICA WHEN 30 MINS IN ROUTE Phone #: ###-#### Inspection requested via web by Rick Montgomery- furnace a/c coil co ok- bubble wrap insulation on R/A needs 3/4" air gap per installation instructions has no gap- need to install the locking caps left by the service ports- send pic for reinspect
MEC19-05005 Final11/20/201911/22/201911/22/2019 2:37:44 PMPPASS
Please call Lisa ###-#### in route to inspection Phone #: ###-#### Inspection requested via web by Justin Osterhout- furnace a/c coil co locking caps ok
MEC19-05279 Pressure Test11/22/201911/22/201911/22/2019 2:09:10 PMPPASS
Kevin Phone #: ###-####- 20lb gas pass- need to sleeve csst piping thru concrete at fireplace location by final- install co detectors if homeowner doesnt have any by final
MEC19-05288 Final11/21/201911/22/201911/22/2019 1:56:25 PMPPASS
Please call Jeremy on your way - ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks- electric furnace only ok
MEC19-05263 Pressure Test11/22/201911/22/201911/22/2019 1:20:45 PMPFAIL
Tim Phone #: ###-#### PLEASE CALL FOR ACCESS- gauge below 20psi- need 2 shutoff valves with open tee between them- single shutoff valve can not have air one side and gas other- need roof access- schedule when ready
MEC19-03725 Final11/22/201911/22/201911/22/2019 1:00:32 PMPPASS
please reach out to Todd if you have any questions ###-####
2nd contact would be Glen ###-####. Thank you. Phone #: ###-#### Inspection requested via web by Yvonne Bowman- 2 RTU finals ok- gas piing ok- smoke detector installed both units- weather tight whips installed
MEC19-03644 Rough-in11/21/201911/22/201911/22/2019 12:32:29 PMPCANC
Inspection of return air plenum work. Would like to schedule after 3:30 if possible, please call when on the way to the house. Phone #: ###-#### Inspection requested via web by JEFFREY DAVIS- should have been conference on R/A
MEC19-03644 Conference11/22/201911/22/201911/22/2019 12:31:46 PMPDONE
Inspection of return air plenum work. Would like to schedule after 3:30 if possible, please call when on the way to the house. Phone #: ###-#### Inspection requested via web by JEFFREY DAVIS- discussed R/A duct above furnace- looks undersized homeowner will find alternative routing and check cfm quantities
MEC19-05296 Rough-in11/22/201911/22/201911/22/2019 12:08:41 PMPNR
Phone #: ###-#### Inspection requested via web by Bryan Palmer
1- need approved man j onsite
2- range duct will install at final
3- family rm and utility rm will have supply ducting completed at final has to work with cabinet guys
4- condensate in crawl has pvc installed 5 feet into crawl to post and beam poly line from pump to that location wasnt any way to acheive grade
5- man j will be updated
6- need to add dryer duct and exhaust fan to permit
MEC19-05296 Pressure Test11/22/201911/22/201911/22/2019 11:48:38 AMAPASS
Phone #: ###-#### Inspection requested via web by Bryan Palmer- 5lb flue pass
MEC19-05293 Pressure Test11/21/201911/22/201911/22/2019 11:28:50 AMAFAIL
Albert Phone #: ###-####- need 30lb max gauge for 20psi test
MEC19-05293 Rough-in11/21/201911/22/201911/22/2019 11:28:20 AMAFAIL
Albert Phone #: ###-####
1- need approved man j onsite
2- need outside air ran on r/i inspection
MEC19-05294 Rough-in11/21/201911/22/201911/22/2019 11:27:43 AMAFAIL
Albert Phone #: ###-####
1- need approved man j onsite
2- need to seal r/a boots
3- outside air ducting needs ran
MEC19-05294 Pressure Test11/21/201911/22/201911/22/2019 11:26:51 AMAFAIL
Albert Phone #: ###-####- need 30lb max gauge for 20psi test
MEC19-04464 Final11/22/201911/22/201911/22/2019 11:03:05 AMAFAIL
Garage code is 2468 Phone #: ###-#### Inspection requested via web by JOSE DUARTE- need approved man j onsite for inspection
MEC19-04534 Final11/22/201911/22/201911/22/2019 10:59:43 AMAFAIL
Garage code is 2468 Phone #: ###-#### Inspection requested via web by JOSE DUARTE- need approved man j onsite
need duct blast test completed and report onsite
MEC19-05289 Final11/21/201911/22/201911/22/2019 10:40:29 AMPPASS
LATE A.M. OR EARLY P.M. FINAL
INSTALLER AL ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt
MEC19-05289 Pressure Test11/21/201911/22/201911/22/2019 10:40:09 AMPPASS
LATE A.M. OR EARLY P.M. GAS P/T
INSTALLER AL ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- 20lb gas pass
MEC19-05296 Rough-in11/21/201911/22/201911/22/2019 10:23:33 AMAFAIL
Phone #: ###-#### Inspection requested via web by Bryan Palmer
1- need to resubmit man j all equipment does not match approved man j
2- who installed exhaust fan? need to add to permit
3- range duct ?
4- family room and utility room need supply registers install per man J
5- flue needs tested
6- condensate pump is in alarm and need to run 3/4 inch pvc from furnace to outside and run minimal poly tube from furnace to outside with grade
7- bedroom 3 shows 4x10 boot not 2 x 14
secondary drain and primary off coil need completed

left notice onsite
MEC19-05001 Final11/22/201911/22/201911/22/2019 9:38:30 AMAPASS
MEC19-05001 Rough-in11/20/201911/22/201911/22/2019 9:37:43 AMAPASS
BARBARA ###-#### CALL 30 MIN PRIOR TO ARRIVAL Phone #: ###-#### Inspection requested via web by Mike Almanza- fireplace R/I ok
MEC19-05194 Final11/19/201911/22/201911/22/2019 9:10:21 AMAPASS
Phone #: ###-#### Inspection requested via web by Mary LaFayette- mini split final ok
MEC19-05194 Rough-in11/22/201911/22/201911/22/2019 9:09:33 AMAPASS
Phone #: ###-#### Inspection requested via web by Mary LaFayette- R/I ok 2 head mini split- ok to cover
MEC19-04608 Rough-in11/21/201911/22/201911/22/2019 8:42:23 AMAPASS
Please call Joe on your way so he can meet you. Please confirm you will be there tomorrow as well. Thank you! Phone #: ###-#### Inspection requested via web by Misty McNabb- R/I ok- need drain pans under both coils and one unit needs flexable copper removed on primary drain- went over onsite with installer
MEC19-05231 Final11/21/201911/22/201911/22/2019 8:18:38 AMAPASS

please call homeowner 30 minutes ahead of time // homeowner number is ###-#### // homeowner is paul Phone #: ###-#### Inspection requested via web by Joseph Profitt- corrections made
MEC19-05164 Final11/22/201911/22/201911/22/2019 7:52:23 AMAPASS
correction made
MEC19-05102 Final11/22/201911/22/201911/22/2019 7:50:37 AMAPASS
furnace a/c coil co locking caps ok- correction made
MEC19-00137 Mec-Aging Inspection11/22/201911/22/201911/22/2019 7:47:14 AM CANC
MEC19-00137 DOC - Permit Expired11/22/201911/22/201911/22/2019 7:47:08 AMAPASS
no calls- no activity- permit expired
MEC19-05217 Final11/19/201911/22/201911/19/2019 8:23:28 AMPCANC
INSTALLER DAVID ###-#### Phone #: ###-#### >> Inspection requested via web by Aaron Alandt Inspection cancelled from web by: Aaron Alandt