Inspections for the day of: Tuesday, November 23, 2010.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorTroy Cobbley
TitleFIRE INSPECTOR
Phone #794-9483
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
FIR10-00032 FIR-Aging Inspection11/23/201011/23/201011/30/2010 2:30:31 PM NR
work is in progress
FIR06-00254 INSP-Conference11/17/201011/23/201011/24/2010 10:56:55 AMADONE
I followed up with Steve Bevans ###-####and he stated that he had just met with Dave Whiting, ADT, and that the project is moving forward. A follow up inspection is set up for next week.
FIR08-00143 FIR-Aging Inspection11/23/201011/23/201011/24/2010 8:50:02 AM NR
I spoke to Brian with Lighting Electric, who was with Ernie, and they were going to address this permit. I also spoke to Charlie with SimplexGrinnell.
FIR10-00465 INSP-Sprinkler Rough-in11/23/201011/23/201011/23/2010 3:24:31 PMPFAIL
The floor plans do not match the actual floor plans. Pendant heads are overspaced, based on Ordinary Hazard Occupancy, off of a wall that is not shown on the plans and a pocket with a mop sink has no protection. When pendants are added it may affect the original remote area since this area is at the far end of a gridded system.
BLD10-02710 FIRE-Final Inspection11/22/201011/23/201011/23/2010 2:48:15 PMAFAIL
Provide the fire extinguishers as discussed and provide the sticker at the main exit.
BLD10-02324 FIRE-Final Inspection11/23/201011/23/201011/23/2010 2:41:21 PMPFAIL
Provide an occupant load sign per review note #1, provide panic hardware per review note #5 and plan sheet #A-1, provide exit discharge lighting per drawing sheet E-1, and repair emergency lighting in the womens restroom.
FIR10-00581 INSP-Final Inspection11/23/201011/23/201011/23/2010 2:04:09 PMPPASS
permit finaled
BLD10-02709 FIRE-Final Inspection11/23/201011/23/201011/23/2010 1:19:40 PMPPASS
Life safety passed
FIR10-00479 INSP-Final Inspection11/22/201011/23/201011/23/2010 11:01:09 AMAPASS
Permit finaled
BLD10-02587 FIRE-Final Inspection11/22/201011/23/201011/23/2010 10:29:51 AMAPASS
life safety passed
BLD10-02038 FIRE-Final Inspection11/22/201011/23/201011/23/2010 9:12:11 AMAPASS
life safety passed
BLD10-02736 FIRE-Final Inspection11/22/201011/23/201011/23/2010 9:07:07 AMAFAIL
I left a message on the contacts voice mail at 8:30 stating I would be there in 30 minutes. I arrived at 9:00 and he was not here. I spoke to a lady in the flowere shop but she was not sure who Robert was and did not have the city approved drawings. No inspection was performed. Robert Phone #: ###-####