ELE11-00317
| Final | 11/23/2011 | 11/23/2011 | 11/23/2011 2:24:18 PM | P | PASS |
|
|
looked at signs, ok final
|
ELE11-02596
| Final | 11/23/2011 | 11/23/2011 | 11/23/2011 2:23:14 PM | P | PASS |
|
|
all covered, just need final Phone #: ###-#### >> Inspection requested via web by Randy Fletcher ok final
|
ELE11-02571
| Rough-In Permanent Service | 11/23/2011 | 11/23/2011 | 11/23/2011 1:55:13 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Alan Lusk corrections made, ri ok, p/s u/g n ok
|
ELE11-02371
| Final | 11/23/2011 | 11/23/2011 | 11/23/2011 12:55:43 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by TOM BICANDI ok final
|
ELE11-00557
| Electrical Rough-In | 11/22/2011 | 11/23/2011 | 11/23/2011 10:25:41 AM | A | PASS |
|
|
Contact is Deeon Martineau Phone #: ###-#### >> Inspection requested via web by Scott Campbell stairwell anop ok cover
|
ELE11-02626
| Rough-In Permanent Service | 11/22/2011 | 11/23/2011 | 11/23/2011 10:03:31 AM | A | PASS |
|
|
If you could please be there AFTER 9 AM as I can''t get there earlier to let you in, have to take son to daycare. Thank you Phone #: ###-#### >> Inspection requested via web by Mark Hennequin ri ok for service only, p/s o/h rec ok
|
ELE11-02571
| Rough-In Permanent Service | 11/21/2011 | 11/23/2011 | 11/23/2011 10:02:32 AM | A | FAIL |
|
|
Phone #: ###-#### >> Inspection requested via web by Alan Lusk called, left correction notice, NEC 210.52(A)(2) shall install receptacles in wall space such that no point is over 6' from outlet, 300.4(A) edge of bored holes shall be 1 1/4" from edge of framing member or add steel plates, BCC shall provide boxes for nm cable, shall provide approved set of plans
|