MEC18-05404
| Rough-in | 11/20/2018 | 11/23/2018 | 11/23/2018 2:37:10 PM | P | PASS |
|
|
Builder will be onsite. Phone #: ###-#### Inspection requested via web by Angie Thome- R/I ok- need to support main duct in crawl 4" minimum above ground by final
|
MEC18-05404
| Pressure Test | 11/20/2018 | 11/23/2018 | 11/23/2018 2:34:47 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Angie Thome- 20lb gas pass
|
MEC18-05267
| Rough-in | 11/21/2018 | 11/23/2018 | 11/23/2018 2:32:19 PM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Ashley Shoecraft- fireplace R/I ok
|
MEC18-05620
| Final | 11/21/2018 | 11/23/2018 | 11/23/2018 1:27:15 PM | P | PASS |
|
|
Please call prior to arrival ###-#### Inspection requested via web by Arielle Hendricks- furnace a/c coil co ok
|
MEC18-04469
| Final | 11/20/2018 | 11/23/2018 | 11/23/2018 9:54:34 AM | A | FAIL |
|
|
access 3715 Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN- need uv protection on line set outside- need to seal/rodent proof line set where enters into crawl- need sediment traps on gas line between shut off valve and appliances(furnace and water heater locations)
|
MEC18-04370
| Final | 11/20/2018 | 11/23/2018 | 11/23/2018 9:50:09 AM | A | FAIL |
|
|
access 3714 Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN- need uv protection on lineset outside- need to seal/rodent proof lineset where enters into crawl space
|
MEC18-05535
| Rough-in | 11/21/2018 | 11/23/2018 | 11/23/2018 9:09:41 AM | A | PART |
|
|
Need partial rough in for area before sheet rock is installed Please call Marvin Jennings for access ###-#### Phone #: ###-#### Inspection requested via web by Jamie Scibior- insulation on ducts above hard lids ok- ok to cover ceiling EXCLUDING ROOM WHERE CLASS 2 HOOD WILL BE INSTALLED still not there- need hood installed for R/I to pass
|