ELE13-01366
| ELE-Aging Inspection | 11/24/2015 | 11/24/2015 | 11/24/2015 3:25:50 PM | | DONE |
|
|
Still under construction
|
ELE13-01374
| ELE-Aging Inspection | 11/24/2015 | 11/24/2015 | 11/24/2015 3:25:26 PM | | DONE |
|
|
Still under construction
|
ELE15-03811
| Electrical Rough-In | 11/24/2015 | 11/24/2015 | 11/24/2015 3:22:44 PM | P | PASS |
|
|
Call Steve when in route. Check in with front desk for visitors badge. Phone #: ###-#### Inspection requested via web by Steve McCloy Wall did not have electrical installed in it. Cubicals to be installed in future. Wall and grid for new office area and hall rough in ok cover
|
ELE15-03468
| Permanent Service | 11/24/2015 | 11/24/2015 | 11/24/2015 2:54:17 PM | P | PASS |
|
|
Re-inspection of electrical service. Contact is Jay Sprik. Phone #: ###-#### Inspection requested via web by Richard Montgomery p/s u/g n ok
|
ELE15-03731
| Rough-In Permanent Service | 11/23/2015 | 11/24/2015 | 11/24/2015 2:20:18 PM | P | PASS |
|
|
Please contact Gary ###-#### with any questions. Phone #: ###-#### Inspection requested via web by Tracy Robertson Rough in ok cover p/s u/g n ok
|
ELE15-02705
| Final | 11/24/2015 | 11/24/2015 | 11/24/2015 2:01:47 PM | P | PASS |
|
|
Jay Phone #: ###-#### Final ok
|
ELE15-02975
| Final | 11/24/2015 | 11/24/2015 | 11/24/2015 1:18:13 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Brad Girard 334.10- NM cable shall not be installed where subject to physical damage. Exposed under over hang on island to receptacle. 406.12- All 15 and 20 amp receptacle outlet installed in a residence shall be tamper resistant type. Verbal with contractor
|
ELE15-03781
| Temporary Service | 11/24/2015 | 11/24/2015 | 11/24/2015 12:25:51 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Rowdy Monroe t/s u/g n ok
|
ELE15-03780
| Temporary Service | 11/24/2015 | 11/24/2015 | 11/24/2015 12:08:04 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Rowdy Monroe t/s u/g n ok
|
ELE15-03777
| Temporary Service | 11/24/2015 | 11/24/2015 | 11/24/2015 11:58:20 AM | P | PASS |
|
|
corrections have been made Phone #: ###-#### Inspection requested via web by David Nelson t/s u/g n ok
|
ELE15-03807
| Rough-In Permanent Service | 11/23/2015 | 11/24/2015 | 11/24/2015 11:34:27 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Dan Rohl Rough in ok cover p/s u/g n ok
|
ELE15-03808
| Electrical Rough-In | 11/23/2015 | 11/24/2015 | 11/24/2015 10:58:17 AM | A | PASS |
|
|
We are requesting a rough-in inspection for tomorrow 11/24/15 in the AM. Our contact is Trent Hammon ###-####, Thank you! Phone #: ###-#### Inspection requested via web by Clint Tate Enter through south door by dumpster. Demizing wall and new bathrooms walls and hardlids rough in ok cover
|
ELE15-03436
| Rough-In Permanent Service | 11/23/2015 | 11/24/2015 | 11/24/2015 10:25:18 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Brandon Hillman Rough in ok cover p/s u/g n ok
|
ESC15-01026
| Random Inspection | 11/24/2015 | 11/24/2015 | 11/24/2015 10:05:02 AM | P | PASS |
|
|
Site clean and contained
|
ELE15-03814
| Temporary Service | 11/24/2015 | 11/24/2015 | 11/24/2015 10:04:00 AM | P | FAIL |
|
|
590.6(B)- Temp power receptacles other than 120 volt shall have GFCI protection. 250 breaker did not trip when tested.
|
ELE15-03814
| Rough-In Permanent Service | 11/23/2015 | 11/24/2015 | 11/24/2015 9:59:47 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by TOM BICANDI Rough in ok cover p/s u/g n ok
|
ELE15-03815
| Temporary Service | 11/24/2015 | 11/24/2015 | 11/24/2015 9:50:40 AM | P | PASS |
|
|
t/s u/g n ok
|
ELE15-03815
| Final | 11/23/2015 | 11/24/2015 | 11/24/2015 9:49:51 AM | A | CANC |
|
|
Phone #: ###-#### Inspection requested via web by Ben Archibald Needed temp service inspection
|
ELE15-03813
| Rough-In Permanent Service | 11/23/2015 | 11/24/2015 | 11/24/2015 9:04:40 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by TOM BICANDI Rough in ok cover p/s u/g n ok
|
ELE15-03813
| Temporary Service | 11/24/2015 | 11/24/2015 | 11/24/2015 9:04:15 AM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by TOM BICANDI 590.6(B)- Temp power other than 120 volt shall have GFCI protection. 250 breaker failed to trip when tested.
|