Inspections for the day of: Tuesday, November 25, 2014.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE12-00974 ELE-Aging Inspection11/25/201411/25/201412/1/2014 9:26:52 AM DONE
called, left message to set up final
ELE14-03252 Electrical Rough-In11/24/201411/25/201411/25/2014 3:16:22 PMPPASS
Phone #: ###-#### Inspection requested via web by Alan Lusk ri ok bath, bedroom
ELE14-02985 Rough-In Permanent Service11/25/201411/25/201411/25/2014 2:34:07 PMPPASS
Inspection requested via web by Eric Brown ri ok, p/s u/g n ok
ELE14-03266 Electrical Rough-In11/25/201411/25/201411/25/2014 1:43:55 PMPPASS
Ground work inspection. For boxes in basement Phone #: ###-#### Inspection requested via web by Chris Chesnut ok cover floor boxes basement, called contractor and ipco to remove meter from temp pole lying on ground, was told only builder can request disconnect
ELE14-03184 Final11/24/201411/25/201411/25/2014 12:39:03 PMAPASS
Jason gaythwaite is our journeyman contact Phone #: ###-#### Inspection requested via web by Kelly Felin ok final
ELE14-03267 Electrical Rough-In11/24/201411/25/201411/25/2014 12:06:59 PMAFAIL
Driveway heat Phone #: ###-#### Inspection requested via web by kevin blackmon called, left message, met builder, NEC 300.5 pvc shall be min 12" deep, BCC shall not cover u/g until inspected, 4-05-33(A)(B) shall use listed equipment
ELE14-03263 Electrical Rough-In11/24/201411/25/201411/25/2014 9:34:04 AMAPASS
will need final Phone #: ###-#### Inspection requested via web by Stuart Welton ri ok
ELE14-03263 Final11/25/201411/25/201411/25/2014 9:33:25 AMAPASS
will need final Phone #: ###-#### Inspection requested via web by Stuart ok final
ELE14-03172 Rough-In Permanent Service11/24/201411/25/201411/25/2014 9:10:57 AMAPASS
Phone #: ###-#### Inspection requested via web by Therrin Robertson ri ok, p/s u/g n ok
ELE14-02196 Electrical Rough-In11/24/201411/25/201411/25/2014 8:18:03 AMAPASS
Rough-in inspection for women''s fitting room. Call Kaden with any questions at ###-####. Phone #: ###-#### Inspection requested via web by Kurtis Moore ok cover womens fitting room, advised contractor that discharge lighting plugs shall be directly over luminaire
ELE14-03206 Final11/24/201411/25/201411/25/2014 7:53:23 AMAFAIL
Kim Orgill was electrician that inspected meter. Phone #: ###-#### Inspection requested via web by Tyler Bowen called to provide address, job id sticker, call for t/s
ELE14-03252 Electrical Rough-In11/24/201411/25/201411/24/2014 9:52:53 PMACANC
Phone #: ###-#### >> Inspection requested via web by Alan Lusk Inspection cancelled from web by: Alan Lusk