Inspections for the day of: Monday, November 26, 2007.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorPat Lass
TitleELE-INSPECTOR
Phone #794-9478
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE07-02973 ELE-Aging Inspection11/26/200711/26/200712/4/2007 11:44:14 AM PASS
No electrical to signs.
ELE07-00003 ELE-Aging Inspection11/26/200711/26/200712/4/2007 10:24:07 AM NR
Called rick and they will schedual a final.
ELE07-01145 Final11/26/200711/26/200711/26/2007 4:46:26 PMPPASS
Scheduled by a contractor via Hello! on 11/26/2007 at 8:15:30 AM. Contact: ###-####.
ELE07-03302 Electrical Rough-In11/26/200711/26/200711/26/2007 3:57:19 PMPPASS
moved utility in bathroom around downstairs. backdoor is unlocked Phone #: ###-#### Internet Inspection Request from: Cevyn Recla
MIS07-00234 ELE-Conference11/26/200711/26/200711/26/2007 3:49:44 PMPFAIL
gary ellwood is renting this place his # is ###-####-- wiring is a mess
250.4 General Requirements for Grounding and Bonding.
(A) Grounded Systems.
Grounding electrode conductor has been disconnected.

310.15 Ampacities for Conductors Rated 0-2000 Volts.
(A) General.
(1) Tables or Engineering Supervision. Ampacities for conductors shall be permitted to be determined by tables or under engineering supervision, as provided in 310.15(B) and (C).
Wires are overfused in panel.
230.24 Clearances.
Service-drop conductors shall not be readily accessible and shall comply with 230.24(A) through (D) for services not over 600 volts, nominal.

If action is not taken on these violations within two days further action may be taken including disconnection of power.
ELE07-01595 Final11/26/200711/26/200711/26/2007 2:49:02 PMPPASS
bernice Phone #: ###-####
ELE06-03143 Electrical Rough-In11/26/200711/26/200711/26/2007 2:12:39 PMPPART
ed ###-####
partial ceiling anop
ELE07-03915 Conference11/26/200711/26/200711/26/2007 1:32:45 PMPPART
bart ###-#### or ###-####
talked about requirements in general
ELE07-02968 ELE-Aging Inspection11/26/200711/26/200711/26/2007 11:43:56 AM PASS
ELE07-02968 DOC - Permit Finaled11/26/200711/26/200711/26/2007 11:43:42 AMPPASS
ELE07-02412 Final11/21/200711/26/200711/26/2007 10:13:05 AMAPASS
Contact Electrician is Randy his cell # is ###-####. Phone #: ###-#### Internet Inspection Request from: Heather Packer
ELE06-02323 Final11/26/200711/26/200711/26/2007 9:30:18 AMAPASS
Scheduled by a contractor via Hello! on 11/26/2007 at 6:26:42 AM. Contact: ###-####.
ELE07-03781 Final11/21/200711/26/200711/26/2007 8:48:11 AMAPASS
final on outlet installed for sprinkler timer Phone #: ###-#### Internet Inspection Request from: Andy Rose