Inspections for the day of: Tuesday, November 26, 2019.
Number of inspections: 23
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Reynolds
TitleMEC INSPECTOR
Phone #208-803-2395
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC19-05278 Final11/25/201911/26/201911/26/2019 3:46:53 PMPPASS
Please call Dave to ensure install is complete. Thank you! ###-#### Phone #: ###-#### Inspection requested via web by Rick Borg
- furnace only co ok
MEC19-05293 Conference11/26/201911/26/201911/26/2019 3:06:14 PMPCANC
Phone #: 2088718789 >> Inspection requested via mobile web by Albert
MEC19-05293 Rough-in11/26/201911/26/201911/26/2019 3:06:00 PMPPASS
Phone #: 2088718789 >> Inspection requested via mobile web by Albert
- R/I ok
MEC19-05294 Conference11/26/201911/26/201911/26/2019 3:05:33 PMPCANC
Phone #: 2088718789 >> Inspection requested via mobile web by Albert
MEC19-05294 Rough-in11/26/201911/26/201911/26/2019 3:05:26 PMPPASS
Phone #: 2088718789 >> Inspection requested via mobile web by Albert
- R/I ok
MEC19-04974 Final11/26/201911/26/201911/26/2019 2:45:30 PMPPASS
PRESSURE TEST W/HVAC TECH AFTER 1:30. PLEASE CALL PATRICK BEFORE SHOWING UP TO SEE IF HE''S THERE--WILL BE THERE SOMETIME AFTER 1 P.M. Phone #: ###-#### Inspection requested via web by SOPHIA FLEMING
- 5lb flue pressure test ok
- final ok
MEC19-04324 Rough-in11/26/201911/26/201911/26/2019 2:17:45 PMPPASS
please contact Glen with any questions Phone #: ###-#### Inspection requested via web by Yvonne Bowman
- bathroom hard lid cover ok
MEC19-05338 Final11/25/201911/26/201911/26/2019 2:06:16 PMPPASS
INSTALLER DUSTIN ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt
- furnace only co ok
MEC19-05331 Final11/25/201911/26/201911/26/2019 1:56:07 PMPNH
INSTALLER DAKOTA ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt
- called installer no answer
- no access to home left notice on front door
MEC19-03972 Final11/26/201911/26/201911/26/2019 1:36:12 PMPFAIL
Dale- call for access Phone #: ###-####
- need to see high and low combustion air openings into mech closet for water heater and furnace
MEC19-05106 Final11/22/201911/26/201911/26/2019 1:25:25 PMPCANC
michael ###-#### Phone #: ###-#### Inspection requested via web by Mike Almanza
MEC19-05106 Rough-in11/22/201911/26/201911/26/2019 1:25:13 PMPCANC
michael ###-#### Phone #: ###-#### Inspection requested via web by Mike Almanza
- homeowner said fireplace installation was reschedule for another date
MEC19-04414 Final11/26/201911/26/201911/26/2019 10:39:36 AMAPASS
Garage code is 2468 call me please when you are heading there so I can bring a ladder, because you will need it. Thank you Phone #: ###-#### Inspection requested via web by JOSE DUARTE
- final ok
MEC19-05340 Rough-in11/25/201911/26/201911/26/2019 10:07:31 AMAPASS
GATE CODE FOR SUB IS 2001 Phone #: ###-#### Inspection requested via web by Sheldon Lebow
- fireplace R/I ok
MEC19-05347 Final11/25/201911/26/201911/26/2019 9:45:24 AMAPASS
Phone #: ###-#### Inspection requested via web by Brian Preece
- final ok
MEC19-05347 Rough-in11/25/201911/26/201911/26/2019 9:45:09 AMAPASS
Phone #: ###-#### Inspection requested via web by Brian Preece
- fireplace R/I ok
MEC19-05347 Pressure Test11/25/201911/26/201911/26/2019 9:44:49 AMAPASS
Phone #: ###-#### Inspection requested via web by Brian Preece
- 20lb gas pressure test ok
MEC19-04691 Final11/25/201911/26/201911/26/2019 9:12:52 AMAFAIL
Walk in refrigeration lines ready to inspect Phone #: ###-#### Inspection requested via web by Clay Bonvillain
- refrigeration lines need UV protection on roof
MEC19-05244 Rough-in11/25/201911/26/201911/26/2019 8:43:51 AMAFAIL
Need fireplace inspection as well Phone #: ###-#### Inspection requested via web by Loren Bailey
- need installation instructions out of fireplace
- gas line needs more supports in crawl
- pressure test fail
- couldn't find dryer vent
- mini split line set/ condensate R/I ok
- two supply runs in crawl R/I ok
- exhaust fan venting R/I ok
MEC19-05244 Pressure Test11/25/201911/26/201911/26/2019 8:41:32 AMAFAIL
Phone #: ###-#### Inspection requested via web by Loren Bailey
- gauge below 20lb
- re test once fixed
MEC19-03990 Rough-in11/25/201911/26/201911/26/2019 8:04:37 AMACANC
cover inspection for 2nd floor Phone #: ###-#### Inspection requested via web by Brandon Sorensen
- 2nd floor cover inspection was given yesterday
MEC19-01928 Mec-Aging Inspection11/26/201911/26/201911/26/2019 8:01:30 AM FAIL
Permit has not been active since 5-30-19 when inspection was cancelled. If work is finished schedule an inspection with homeowner. Permit will expired at next mechanical aging inspecton if not active.
MEC19-01907 Mec-Aging Inspection11/26/201911/26/201911/26/2019 7:59:45 AM FAIL
still need access to vent connection at furnace. Schedule inspection with homeowner