BLD00-03212
| BLD-Final | 11/26/2001 | 11/27/2001 | 11/27/2001 12:00:00 AM | A | NR |
|
|
call bill first to meet you there ###-####; need state elev tag & conc test report. reca 11/27/2001 11:10:09 AM ll 11/27/2001 11:10:12 AM
|
BLD99-03383
| BLD-Energy code compliance | 11/26/2001 | 11/27/2001 | 11/27/2001 12:00:00 AM | A | NR |
|
|
LORA ###-####; need arch's approval /letter to delete 1hr const at north wall. will submit 11/27/2001 1:48:52 PM
|
BLD00-03538
| BLD-Conference | 11/27/2001 | 11/27/2001 | 11/27/2001 12:00:00 AM | A | PART |
|
|
Added by Inspector: 340 On 11/27/2001 11:13:18 AM need specs for expansion joint & firestops at occ. sep.
|
BLD00-01649
| BLD-Conference | 11/27/2001 | 11/27/2001 | 11/27/2001 12:00:00 AM | A | PART |
|
|
Added by Inspector: 340 On 11/27/2001 9:20:54 AM w/new architect & Lee B. re courtroom walls, still need detail for revised horiz. exit at 4th fl; keep c/n. (Richard Hatcher has left L.C.A. met Debora onsite as new arch.)
|
BLD01-02564
| BLD-Framing/Rough-in | 11/27/2001 | 11/27/2001 | 11/27/2001 12:00:00 AM | P | FAIL |
|
|
Scheduled by a contractor via Hello! on 11/27/2001 at 09:25:55. Contact: ###-####...nr, need fireblocks, hvac r/i. etc. Has stamped detail for deletion of fnd. below existing brg wall, will review & consult as I am unable to visually determine load path 11/27/2001 3:06:33 PM
|
BLD01-01643
| BLD-Final | 11/26/2001 | 11/27/2001 | 11/27/2001 12:00:00 AM | P | NR |
|
|
###-####
|
BLD01-02570
| BLD-Framing/Rough-in | 11/27/2001 | 11/27/2001 | 11/27/2001 12:00:00 AM | P | FAIL |
|
|
Scheduled by a contractor via Hello! on 11/27/2001 at 11:15:58. Contact: ###-####. c/n, fireblocks, airseal, straps, roof vent./flashing. ok to insul ...verify hvac. 11/27/2001 3:42:27 PM
|
BLD99-03383
| BLD-Framing/Rough-in | 11/27/2001 | 11/27/2001 | 11/27/2001 12:00:00 AM | P | FAIL |
|
|
Added by Inspector: 340 On 11/27/2001 1:47:41 PM bsmt: c/n re corridor penetrations, lg. panel box at elec. rm... grid wires, pods;labels at rated doors & glass. repair spray-on F.P. at beams, pan over garage, etc. Verify fire-smoke dampers at hvac at elev lobbies/corridor. ok to tile 2hr exit pass. at 1st fl, grid ok.
|
BLD01-01693
| BLD-Conference | 11/27/2001 | 11/27/2001 | 11/27/2001 12:00:00 AM | P | PART |
|
|
Added by Inspector: 340 On 11/27/2001 3:37:51 PM w/ rick at site re phase 2
|
BLD01-02523
| BLD-Energy code compliance | 11/27/2001 | 11/27/2001 | 11/27/2001 12:00:00 AM | P | PART |
|
|
Added by Inspector: 340 On 11/27/2001 4:49:29 PM walls ok
|
BLD01-02523
| BLD-Framing/Rough-in | 11/27/2001 | 11/27/2001 | 11/27/2001 12:00:00 AM | P | PASS |
|
|
###-#### c/n ok 11/27/2001 5:51:47 PM
|
BLD01-02581
| BLD-Foundation | 11/27/2001 | 11/27/2001 | 11/27/2001 12:00:00 AM | P | PASS |
|
|
###-#### ANDY ftg, col connections ok 11/27/2001 4:34:58 PM
|