Inspections for the day of: Wednesday, November 27, 2002.
Number of inspections: 9
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE02-03109 Temporary Service11/26/200211/27/200211/27/2002 12:00:00 AMAPASS
Scheduled by a contractor via Hello! on 11/26/2002 at 13:02:21. Contact: ###-####. ok t/s u/g new 11/27/2002 1:34:27 PM
ELE02-03697 Rough-In Permanent Service11/26/200211/27/200211/27/2002 12:00:00 AMANR
ron ###-#### called electrical contractor, 11/27/2002 11:02:07 AM
ELE02-03694 Electrical Rough-In11/26/200211/27/200211/27/2002 12:00:00 AMAFAIL
Phone #: ###-#### Internet Inspection Request from: Amy Lawson cor. posted called 210.52(A&B) needs reuired outlets and small appliance branch circuit for new dinning and pantry area 314.16 cutin box, 300.4 nail and 11/4 , 110.12(A) replace plastic boxes with unused KOs, all make up shall be complete 11/27/2002 11:49:57 AM
ELE02-02841 Final11/27/200211/27/200211/27/2002 12:00:00 AMPPASS
emmett; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie final ok survey posted called 210.8 master bath, 250.148 wiremold box at micro wave 11/27/2002 6:21:51 PM
ELE02-02181 Final11/27/200211/27/200211/27/2002 12:00:00 AMPPART
Scheduled by a contractor via Hello! on 11/27/2002 at 11:23:43. Contact: ###-####. temp occupancy for shop and RV storage ok 11/27/2002 6:54:52 PM
ELE02-03701 Electrical Rough-In11/27/200211/27/200211/27/2002 12:00:00 AMPPART
conference with contractor ok
ELE02-03642 Final11/21/200211/27/200211/27/2002 12:00:00 AMPFAIL
dave; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie cor. posted called 210.52(A ) required outlets for wall spacing and 2ft wall in bed rm/ office 11/27/2002 4:42:59 PM
ELE02-01798 Electrical Rough-In11/22/200211/27/200211/27/2002 12:00:00 AMPPASS
Scheduled by a contractor via Hello! on 11/22/2002 at 13:41:42. Contact: ###-####. ok 11/27/2002 5:38:00 PM
ELE02-03133 Electrical Rough-In11/26/200211/27/200211/27/2002 12:00:00 AMPPART
Phone #: ###-#### Internet Inspection Request from: Amy Lawson 1st and 2nd floor conveyor wiring 11/27/2002 4:09:24 PM