FIR07-00637
| INSP-Sprinkler Rough-in | 11/26/2007 | 11/27/2007 | 11/27/2007 5:51:04 PM | P | PART |
|
|
The north canopy piping has been corrected and can be covered. The west canopy piping has not been corrected and can not be covered. The remaining hard lids on the second floor can be covered. These were the only three items inspected today.
|
FIR07-00770
| INSP-Final Inspection | 11/26/2007 | 11/27/2007 | 11/27/2007 3:21:06 PM | A | FAIL |
|
|
The duct smoke detectors still need to be tested. Per tim not all of the units are shutting down upon detection of smoke. The notification circuits have been repaired and tested. The smoke detectors located over the nac panels have been relocated to the deck and tested.
|
BLD07-01138
| FIRE-Final Inspection | 11/26/2007 | 11/27/2007 | 11/27/2007 3:17:22 PM | P | PASS |
|
|
life safety passed
|
BLD07-01151
| FIRE-Final Inspection | 11/27/2007 | 11/27/2007 | 11/27/2007 3:16:21 PM | P | PASS |
|
|
life safety passed.
|
FIR07-00528
| INSP-Final Inspection | 11/27/2007 | 11/27/2007 | 11/27/2007 2:31:52 PM | P | PASS |
|
|
permit finaled
|
BLD07-00735
| FIRE-Final Inspection | 11/27/2007 | 11/27/2007 | 11/27/2007 2:31:10 PM | P | PASS |
|
|
Life safety passed
|
BLD07-02898
| FIRE-Final Inspection | 11/27/2007 | 11/27/2007 | 11/27/2007 1:41:46 PM | P | FAIL |
|
|
See the city approved plans for locations of the deficiencies.
|
BLD07-01553
| FIRE-Final Inspection | 11/27/2007 | 11/27/2007 | 11/27/2007 1:27:56 PM | P | FAIL |
|
|
Need to have original copy of approved set of plans with plan review notes on site.Also need to add building address on front of building.Per KR
|
FIR07-00824
| INSP-Sprinkler Rough-in/Hydro | 11/27/2007 | 11/27/2007 | 11/27/2007 12:34:52 PM | P | PASS |
|
|
Underground hydro test passed
|
BLD07-03032
| FIRE-Final Inspection | 11/26/2007 | 11/27/2007 | 11/27/2007 11:53:25 AM | A | PASS |
|
|
Permit finaled.
|
BLD07-01261
| FIRE-Final Inspection | 11/27/2007 | 11/27/2007 | 11/27/2007 11:46:40 AM | P | PASS |
|
|
All life safety corrections were made including new set of city aproved set of sprinkler plans with changes..Per KR
|
FIR07-00782
| INSP-Final Inspection | 11/27/2007 | 11/27/2007 | 11/27/2007 11:43:04 AM | P | PASS |
|
|
overhead finaled, new set of city approved plans on site with all changesmade and approved..Per KR
|
FIR07-00756
| INSP-Final Inspection | 11/27/2007 | 11/27/2007 | 11/27/2007 11:40:27 AM | P | PASS |
|
|
Underground fire permit finaled
|
FIR07-00640
| INSP-Final Inspection | 11/21/2007 | 11/27/2007 | 11/27/2007 10:28:16 AM | A | CANC |
|
|
###-#### - bud Cancelled due to additional strobe being required on the latest plans.
|
BLD07-01225
| FIRE-Final Inspection | 11/26/2007 | 11/27/2007 | 11/27/2007 8:58:45 AM | A | PASS |
|
|
life safety passed.
|
FIR06-00178
| INSP-Final Inspection | 11/21/2007 | 11/27/2007 | 11/27/2007 8:12:12 AM | A | PASS |
|
|
Permit finaled
|