Inspections for the day of: Monday, November 28, 2005.
Number of inspections: 9
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE05-04252 Electrical Rough-In11/28/200511/28/200511/28/2005 4:23:47 PMPNR
###-#### - lynn Note: underground will call when ready
ELE05-03822 Electrical Rough-In11/28/200511/28/200511/28/2005 3:58:23 PMPCANC
marlene; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles see conf
ELE05-04230 Final11/21/200511/28/200511/28/2005 3:56:13 PMPPASS
cindi ###-#### told owner to put on recpt faceplate and plug one opening in jb. ok to final
ELE05-03917 Electrical Rough-In11/28/200511/28/200511/28/2005 2:07:09 PMPPASS
ok for cover -gary; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie--call 1st for access ok to cover bath, added recpt by sink
ELE05-04259 Rough-In Permanent Service11/28/200511/28/200511/28/2005 12:24:27 PMPFAIL
contact will be Rowdy; Phone #: ###-#### Internet Inspection Request from: Rowdy Monroe called contr, left corr notice, 312.5 abrasion protection shall be provided for conductors entering enclosures, 300.4(A) and (D) 1 1/4" shall be maintained for bored holes and nm cable from edge of framing member, BCC all make-up shall be done(box on floor in hall)
ELE05-02426 Final11/22/200511/28/200511/28/2005 9:18:41 AMAPASS
Phone #: ###-#### Internet Inspection Request from: Nikki Day corr made, card signed earlier, ok to final
ELE05-04193 Electrical Rough-In11/27/200511/28/200511/28/2005 9:03:52 AMAFAIL
give paul a call if any problems or questions. Internet Inspection Request from: Paul Young called contr, left corr notice,312.5 conductors shall have abrasion protection, 300.4(A) and (D) bored holes and nm cable shall be 1 1/4" from edge of framing member
ELE05-04251 Temporary Service11/23/200511/28/200511/28/2005 8:50:40 AMACANC
Phone #: ###-#### Internet Inspection Request from: Todd Holbrook Inspection cancelled from web by: Todd Holbrook
ELE05-03822 Conference11/28/200511/28/200511/28/2005 12:00:00 AMPDONE
marlene; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles met owner, they weren't done with requirement for ri, so reviewed all make-up shall be done, cable and emt shall be secured, ground screws shall be used, plastic box shall be changed to metal for emt, reviewed heater reqm'ts and flex from stub-up.