ELE05-04252
| Electrical Rough-In | 11/28/2005 | 11/28/2005 | 11/28/2005 4:23:47 PM | P | NR |
|
|
###-#### - lynn Note: underground will call when ready
|
ELE05-03822
| Electrical Rough-In | 11/28/2005 | 11/28/2005 | 11/28/2005 3:58:23 PM | P | CANC |
|
|
marlene; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles see conf
|
ELE05-04230
| Final | 11/21/2005 | 11/28/2005 | 11/28/2005 3:56:13 PM | P | PASS |
|
|
cindi ###-#### told owner to put on recpt faceplate and plug one opening in jb. ok to final
|
ELE05-03917
| Electrical Rough-In | 11/28/2005 | 11/28/2005 | 11/28/2005 2:07:09 PM | P | PASS |
|
|
ok for cover -gary; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie--call 1st for access ok to cover bath, added recpt by sink
|
ELE05-04259
| Rough-In Permanent Service | 11/28/2005 | 11/28/2005 | 11/28/2005 12:24:27 PM | P | FAIL |
|
|
contact will be Rowdy; Phone #: ###-#### Internet Inspection Request from: Rowdy Monroe called contr, left corr notice, 312.5 abrasion protection shall be provided for conductors entering enclosures, 300.4(A) and (D) 1 1/4" shall be maintained for bored holes and nm cable from edge of framing member, BCC all make-up shall be done(box on floor in hall)
|
ELE05-02426
| Final | 11/22/2005 | 11/28/2005 | 11/28/2005 9:18:41 AM | A | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Nikki Day corr made, card signed earlier, ok to final
|
ELE05-04193
| Electrical Rough-In | 11/27/2005 | 11/28/2005 | 11/28/2005 9:03:52 AM | A | FAIL |
|
|
give paul a call if any problems or questions. Internet Inspection Request from: Paul Young called contr, left corr notice,312.5 conductors shall have abrasion protection, 300.4(A) and (D) bored holes and nm cable shall be 1 1/4" from edge of framing member
|
ELE05-04251
| Temporary Service | 11/23/2005 | 11/28/2005 | 11/28/2005 8:50:40 AM | A | CANC |
|
|
Phone #: ###-#### Internet Inspection Request from: Todd Holbrook Inspection cancelled from web by: Todd Holbrook
|
ELE05-03822
| Conference | 11/28/2005 | 11/28/2005 | 11/28/2005 12:00:00 AM | P | DONE |
|
|
marlene; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles met owner, they weren't done with requirement for ri, so reviewed all make-up shall be done, cable and emt shall be secured, ground screws shall be used, plastic box shall be changed to metal for emt, reviewed heater reqm'ts and flex from stub-up.
|