Inspections for the day of: Wednesday, November 28, 2007.
Number of inspections: 15
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE06-01898 ELE-Aging Inspection11/28/200711/28/200712/3/2007 7:35:33 AM DONE
checked with 315, said everything done
ELE07-03614 Electrical Rough-In11/27/200711/28/200711/28/2007 4:10:59 PMPFAIL
harry Phone #: ###-#### met owner, told BCC all make-up shall be done, NEC 300.4(D) edge of nm cable shall be 1 1/4" from edge of framing member
ELE06-02051 ELE-Aging Inspection11/28/200711/28/200711/28/2007 3:11:26 PM DONE
see final
ELE06-02051 Final11/28/200711/28/200711/28/2007 3:09:45 PMPPASS
looked at sign, ok to final
ELE07-03943 Electrical Rough-In11/28/200711/28/200711/28/2007 2:57:11 PMPPASS
Mike Phone #: ###-#### ok to cover walls only
ELE07-03945 Electrical Rough-In11/28/200711/28/200711/28/2007 2:04:07 PMPPASS
Phone #: ###-#### Internet Inspection Request from: Kerri Hamilton ric ok replacement fixtures
ELE07-03759 Electrical Rough-In11/28/200711/28/200711/28/2007 1:05:35 PMPCANC
Re-inspection. the later afternoon if possible.

Thank you! Phone #: ###-#### Internet Inspection Request from: Ryan Christensen Inspection cancelled from web by: Ryan Christensen
ELE07-03650 Final11/28/200711/28/200711/28/2007 12:47:54 PMPPART
lynn - partial - ac on back order Phone #: ###-#### called contractor, left correction notice,NEC 210.62 shall install receptacle s for show windows for each 12' or fraction thereof, BCC all equipment shall be installed- a/c, address shall be posted, signed t/o card
ELE07-02328 Final11/27/200711/28/200711/28/2007 10:54:18 AMAPASS
the contractor didn''t ever call me back to finish. Phone #: ###-#### Internet Inspection Request from: Andy Derrick ok to final
ELE07-03290 Electrical Rough-In11/27/200711/28/200711/28/2007 10:18:37 AMAPASS
larry Phone #: ###-#### items added after conference, ric ok
ELE06-00402 Final11/27/200711/28/200711/28/2007 9:39:22 AMAPASS
This was finalled the day I did the job. Phone #: ###-#### Internet Inspection Request from: Andy Derrick called contr about label and process for service change, ok to final
ELE07-03929 Electrical Rough-In11/27/200711/28/200711/28/2007 9:23:09 AMAPASS
sue Phone #: ###-#### called contr, ric ok
ELE07-03929 Final11/28/200711/28/200711/28/2007 9:22:19 AMAPASS
sue Phone #: ###-#### ok to final
ELE07-00573 Conference11/27/200711/28/200711/28/2007 8:58:50 AMADONE
Scheduled by a contractor via Hello! on 11/27/2007 at 12:45:14 PM. Contact: ###-####. couldn't get electrician on phone, left message, told general contractor what required to get field evauation for x-ray machine
ELE07-03806 Rough-In Permanent Service11/27/200711/28/200711/28/2007 8:08:22 AMAPASS
R.I. Permanent Service. Padlock w/ Purple tape combo#7217. Kelly Tarter. Phone #: ###-#### Internet Inspection Request from: Kristopher Wilson corr made, ric ok u/g service to tower area, p/s u/g n ok