ELE07-03657
| Electrical Rough-In | 11/28/2007 | 11/28/2007 | 11/28/2007 5:04:54 PM | P | FAIL |
|
|
linda - please call 1/2 hr prior to inspection Phone #: ###-#### home owner did not do the work she staed that she would get an electrical contractor to complete the job. note service change is incorrect needs two ground rods, ground water system, put grounding electrode conductor & grounded conductor on same bus bar, proper breakers for wire size, boxes for lights over bathrm vanity, & all grounding condutors in boxes shall tied together.
|
ELE07-03511
| Final | 11/28/2007 | 11/28/2007 | 11/28/2007 4:32:15 PM | P | PASS |
|
|
alan Phone #: ###-#### ok final
|
ELE07-03932
| Electrical Rough-In | 11/27/2007 | 11/28/2007 | 11/28/2007 3:35:56 PM | A | PEND |
|
|
Please call at least 30 mins prior to inspection--lyndon Phone #: ###-#### electrical contractor that did the work needs to get a permit for the work done. the electrical that took this permit is aware there will be no refund.
|
ELE07-03729
| Final | 11/28/2007 | 11/28/2007 | 11/28/2007 2:12:56 PM | P | CANC |
|
|
call ###-#### for access code. We need a final ceiling inspection. Phone #: ###-#### Internet Inspection Request from: Alison Pennington wrong type of inspection
|
ELE07-03729
| Electrical Rough-In | 11/28/2007 | 11/28/2007 | 11/28/2007 2:12:26 PM | P | PASS |
|
|
call ###-#### for access code. We need a final ceiling inspection. Phone #: ###-#### Internet Inspection Request from: Alison Pennington ok cover ceiling only
|
ELE07-03706
| Electrical Rough-In | 11/28/2007 | 11/28/2007 | 11/28/2007 2:11:42 PM | P | FAIL |
|
|
robert Note: cover ceiling tile Phone #: ###-#### correction nec330.30(B) cable shall be supported within 12inch of all boxes
|
ELE07-03414
| Final | 11/28/2007 | 11/28/2007 | 11/28/2007 1:08:18 PM | P | PASS |
|
|
Contact is Jay Sprik. Phone #: ###-#### Internet Inspection Request from: Richard Montgomery ok final
|
ELE07-00511
| Final | 11/27/2007 | 11/28/2007 | 11/28/2007 11:53:03 AM | A | PASS |
|
|
mike Phone #: ###-#### ok final
|
ELE07-03922
| Electrical Rough-In | 11/27/2007 | 11/28/2007 | 11/28/2007 10:13:40 AM | A | PASS |
|
|
DAVE BRADSHAW - CALL IF THERE ARE ANY QUESTIONS - UFER GROUND Phone #: ###-#### Internet Inspection Request from: Randy Vail ok cover grounding conductor
|
ELE07-01391
| Final | 11/26/2007 | 11/28/2007 | 11/28/2007 10:12:55 AM | A | PASS |
|
|
CONTACT: MARK KNIGHT Phone #: ###-#### Internet Inspection Request from: Deb Gooden ok final note signed card
|
ELE07-03414
| Final | 11/27/2007 | 11/28/2007 | 11/28/2007 8:51:25 AM | A | NR |
|
|
jay Phone #: ###-#### arcfault will not reset & no furnace disconnect
|