ELE10-01638
| ELE-Aging Inspection | 11/28/2016 | 11/28/2016 | 11/29/2016 12:04:46 PM | | DONE |
|
|
Called and left a message
|
ELE16-03700
| Final | 11/21/2016 | 11/28/2016 | 11/29/2016 6:02:21 AM | P | NR |
|
|
Phone #: ###-#### Inspection requested via web by Louis Keller No final at this time
|
ELE16-03700
| Permanent Service | 11/28/2016 | 11/28/2016 | 11/28/2016 2:25:05 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Louis Keller p/s o/h rec ok
|
ELE16-03515
| Electrical Rough-In | 11/28/2016 | 11/28/2016 | 11/28/2016 1:38:11 PM | P | PASS |
|
|
Whole house rough-in ok cover
|
ELE16-03484
| Final | 11/26/2016 | 11/28/2016 | 11/28/2016 9:26:37 AM | A | FAIL |
|
|
garage door is installed, side door is open Phone #: ###-#### Inspection requested via web by todd cline 230.71 Shall not exceed more then 6 service disc 210.52(g)(1) Branch circuits suppling garage outlets shall not serve any outside receptacles 330.12 Type MC cable shall not be used where subject to physical damage 408.32(d) Back fed devices shall fastened in place
|
ELE16-03515
| Electrical Rough-In | 11/23/2016 | 11/28/2016 | 11/28/2016 8:44:11 AM | A | NR |
|
|
Jason Phone #: ###-#### Not ready at this time missing nailplates and KO seals in panel
|