ELE07-01371
| Final | 11/28/2007 | 11/29/2007 | 11/29/2007 4:13:06 PM | P | FAIL |
|
|
CARL Phone #: ###-#### met owner, left correction notice, nec 408.4 circuit directory shall be complete, clear and concise for each circuit, 312.5 abrasion protection shall be provided for all conductors entering enclosure ( gec), 110.12(A) all unused openings shall be closed, in panel ( breaker blanks), 210.70(A)(2)(c) shall provide lighting switch at top of stairs and at bottom
|
ELE07-03671
| Final | 11/29/2007 | 11/29/2007 | 11/29/2007 3:22:03 PM | P | PASS |
|
|
Kevin Brovetto Electrician Phone #: ###-#### Internet Inspection Request from: Jim Burnette ok to final, signed structural card
|
ELE07-03945
| Final | 11/29/2007 | 11/29/2007 | 11/29/2007 2:37:00 PM | P | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Kerri Hamilton ok to final, no card, already signed for occupancy
|
ELE07-03933
| Electrical Rough-In | 11/29/2007 | 11/29/2007 | 11/29/2007 1:57:10 PM | P | PASS |
|
|
Call Stan Olivia ###-#### for access. He will be home this pm for you. Phone #: ###-#### Internet Inspection Request from: BRENDA HURST ric ok
|
ELE07-03933
| Final | 11/29/2007 | 11/29/2007 | 11/29/2007 1:52:11 PM | P | PASS |
|
|
Call Stan Olivia ###-#### for access. He will be home this pm for you. Phone #: ###-#### Internet Inspection Request from: BRENDA HURST ok to final
|
ELE07-03955
| Permanent Service | 11/29/2007 | 11/29/2007 | 11/29/2007 1:31:33 PM | P | PASS |
|
|
chuck Phone #: ###-#### p/s u/g rec ok
|
ELE07-03670
| Final | 11/29/2007 | 11/29/2007 | 11/29/2007 12:34:24 PM | P | PASS |
|
|
Kevin Brovetto Electrician Phone #: ###-#### Internet Inspection Request from: Jim Burnette ok to final, signed structural card
|
ELE07-02885
| Permanent Service | 11/28/2007 | 11/29/2007 | 11/29/2007 10:29:59 AM | A | PASS |
|
|
pat - please call 1/2 hr prior to inspection Phone #: ###-#### p/s u/g rec ok
|
ELE07-00573
| Conference | 11/28/2007 | 11/29/2007 | 11/29/2007 10:05:31 AM | A | DONE |
|
|
Scheduled by a contractor via Hello! on 11/28/2007 at 3:29:58 PM. Contact: ###-####. met gen contr, x-ray man, talked about listing for x-ray machine, he will let 324 know if ok via UL.
|
ELE07-02992
| Final | 11/28/2007 | 11/29/2007 | 11/29/2007 9:36:04 AM | A | PASS |
|
|
TIM Phone #: ###-#### called contractor, ok to final
|
ELE07-02790
| Electrical Rough-In | 11/28/2007 | 11/29/2007 | 11/29/2007 8:11:40 AM | A | PASS |
|
|
Swimming Pool Bonding Grid Inspection. Please call Rowdy with questions @ ###-#### Phone #: ###-#### Internet Inspection Request from: Rowdy Monroe ok to pour equipotential plane only
|