Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE10-02467 ELE-Aging Inspection11/29/201111/29/201112/1/2011 3:34:42 PM DONE
still under construction, Home owner Kathleen said completion should be soon.
ELE11-02665 Electrical Rough-In11/28/201111/29/201111/30/2011 10:10:12 AMAFAIL
Geoff Hannaford is contact ###-####, please call him ahead to meet him there. thank you Phone #: ###-#### >> Inspection requested via web by Debby Ellis NEC 240.21Shall have over current protection on secondary side of sepately dervid system
ELE11-02678 Electrical Rough-In11/29/201111/29/201111/29/2011 3:36:50 PMPNR
Phone #: ###-#### >> Inspection requested via web by Stuart Welton
ELE11-02635 Electrical Rough-In11/28/201111/29/201111/29/2011 2:24:35 PMPPASS
Cal Phone #: ###-#### >> Inspection requested via web by cal crosby rough-in ok cover
ELE11-02662 Electrical Rough-In11/29/201111/29/201111/29/2011 1:59:33 PMPPASS
Please give me half an hour notice to insure access Thanks Shaun ###-#### Phone #: ###-#### >> Inspection requested via web by Shaun Kirkman rough-in ok cover basement
ELE11-02675 Electrical Rough-In11/29/201111/29/201111/29/2011 1:44:33 PMPNR
Phone #: ###-#### >> Inspection requested via web by Barbara Szurgot
ELE11-02614 Electrical Rough-In11/29/201111/29/201111/29/2011 1:30:33 PMPFAIL
roger - please call for access Phone #: ###-#### NEC 330.12(1) MC cable shall not be installed where subject to physical damage 1 1/4 spacing from edge of framing member
ELE11-02563 Electrical Rough-In11/29/201111/29/201111/29/2011 1:12:32 PMPPASS
Underground inspection Phone #: ###-#### >> Inspection requested via web by Kathy Smith rough-in ok cover underground conduits
ELE11-02562 Electrical Rough-In11/29/201111/29/201111/29/2011 1:04:16 PMPFAIL
Jeff Phone #: ###-#### NEC 300.4(A) Shall not staple NM cable within 1 1/4 of the edge of framing members. NEC 334.30 Shall staple NM cable within 12 inches of box
ELE11-00755 Final11/29/201111/29/201111/29/2011 12:39:37 PMPPASS
bill Phone #: ###-#### final ok
ELE11-02623 Electrical Rough-In11/28/201111/29/201111/29/2011 12:21:00 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Paul Young rough-in ok cover basement
ELE11-02578 Final11/28/201111/29/201111/29/2011 12:03:31 PMAFAIL
call 30 minutes prior for access ###-#### Phone #: ###-#### >> Inspection requested via web by John VanZandt Open ground in bedroom circuit
ELE11-02540 Final11/29/201111/29/201111/29/2011 9:44:23 AMAPASS
Call for lock box code if it is locked Phone #: ###-#### >> Inspection requested via web by Lynn Cable final ok
ELE11-02667 Conference11/28/201111/29/201111/29/2011 9:20:34 AMADONE
call rock when you will be there Phone #: ###-#### >> Inspection requested via web by ERIC CENTERS Discussed receptacle spaceing on kitchen counter tops with large windows
ELE11-02477 Final11/28/201111/29/201111/29/2011 8:31:02 AMAPASS
please call the builder for access at ###-####. Phone #: ###-#### >> Inspection requested via web by ERIC CENTERS final ok
ESC11-00192 General Inspection11/29/201111/29/2011