Inspections for the day of: Thursday, November 29, 2018.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE18-04555 Electrical Rough-In11/28/201811/29/201811/29/2018 2:48:53 PMPPASS
Inspect walls and ceilings for cover. Phone #: ###-#### Inspection requested via web by Jeremy Cloud
Walls and ceilings rough in ok cover
ELE18-04554 Electrical Rough-In11/28/201811/29/201811/29/2018 2:42:57 PMPPASS
Inspect walls and ceilings for cover. Phone #: ###-#### Inspection requested via web by Jeremy Cloud
Walls and ceilings rough in ok cover
ELE18-03979 Rough-In Permanent Service11/29/201811/29/201811/29/2018 2:02:59 PMPPASS
Phone #: ###-#### Inspection requested via web by Alan Lusk
rough in ok cover p/s u/g n ok
ELE18-02826 Final11/29/201811/29/201811/29/2018 1:25:32 PMPPASS
Donny Phone #: ###-#### Final ok
ELE18-04301 Rough-In Permanent Service11/28/201811/29/201811/29/2018 1:25:08 PMPFAIL
Phone #: ###-#### Inspection requested via web by Bob Glenn
110.3- All electrical equipment shall be listed for installation. Flexible cord for remote hood motor in 2nd floor attic does not have identification. Open conductors in attic to plug connection in attic. Shall be secured and supported. If listed shall be protected from damage where ran thru bored holes that do not maintain 1 1/4" from framing surface.
314.25- Recessed can in master bath over tub junction box cover shall be completely installed flush with box to totally cover box opening.
334 12 NM cable shall not be installed where subject to physical damage. Under stair installed where drywall will hit when it is installed.
ELE18-04300 Temporary Service11/29/201811/29/201811/29/2018 12:22:39 PMAPASS
Phone #: ###-#### Inspection requested via web by Bob Glenn t/s u/g n ok
ELE18-01439 Electrical Rough-In11/29/201811/29/201811/29/2018 11:52:27 AMAPASS
Rough-in inspection for (3) new outlets on (2) newly exposed existing walls in dining / living rooms. Thank you! Phone #: ###-#### Inspection requested via web by Adam Staigle
Areas noted and 1 additional receptacle added in hall as well. Rough in ok cover
ELE18-03469 Final11/29/201811/29/201811/29/2018 11:28:00 AMAPASS
code 4224 Phone #: ###-#### Inspection requested via web by Bob Glenn
Final ok
ELE18-04534 Electrical Rough-In11/28/201811/29/201811/29/2018 11:03:42 AMAPASS
Phone #: ###-#### Inspection requested via web by Mark M
Hardlids not ready, walls only rough in ok cover
ELE18-04536 Electrical Rough-In11/28/201811/29/201811/29/2018 11:02:37 AMAPASS
Phone #: ###-#### Inspection requested via web by Mark M
Under slab for low voltage control cords for equipment rough in ok cover
ELE18-03297 Final11/28/201811/29/201811/29/2018 11:01:14 AMAPASS
Phone #: ###-#### Inspection requested via web by Mark M Final ok
ELE18-03827 Final11/28/201811/29/201811/29/2018 8:52:19 AMAPASS
garage code 2468 Phone #: ###-#### Inspection requested via web by Darryn Coburn Final ok