ELE18-04555
| Electrical Rough-In | 11/28/2018 | 11/29/2018 | 11/29/2018 2:48:53 PM | P | PASS |
|
|
Inspect walls and ceilings for cover. Phone #: ###-#### Inspection requested via web by Jeremy Cloud Walls and ceilings rough in ok cover
|
ELE18-04554
| Electrical Rough-In | 11/28/2018 | 11/29/2018 | 11/29/2018 2:42:57 PM | P | PASS |
|
|
Inspect walls and ceilings for cover. Phone #: ###-#### Inspection requested via web by Jeremy Cloud Walls and ceilings rough in ok cover
|
ELE18-03979
| Rough-In Permanent Service | 11/29/2018 | 11/29/2018 | 11/29/2018 2:02:59 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Alan Lusk rough in ok cover p/s u/g n ok
|
ELE18-02826
| Final | 11/29/2018 | 11/29/2018 | 11/29/2018 1:25:32 PM | P | PASS |
|
|
Donny Phone #: ###-#### Final ok
|
ELE18-04301
| Rough-In Permanent Service | 11/28/2018 | 11/29/2018 | 11/29/2018 1:25:08 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Bob Glenn 110.3- All electrical equipment shall be listed for installation. Flexible cord for remote hood motor in 2nd floor attic does not have identification. Open conductors in attic to plug connection in attic. Shall be secured and supported. If listed shall be protected from damage where ran thru bored holes that do not maintain 1 1/4" from framing surface. 314.25- Recessed can in master bath over tub junction box cover shall be completely installed flush with box to totally cover box opening. 334 12 NM cable shall not be installed where subject to physical damage. Under stair installed where drywall will hit when it is installed.
|
ELE18-04300
| Temporary Service | 11/29/2018 | 11/29/2018 | 11/29/2018 12:22:39 PM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Bob Glenn t/s u/g n ok
|
ELE18-01439
| Electrical Rough-In | 11/29/2018 | 11/29/2018 | 11/29/2018 11:52:27 AM | A | PASS |
|
|
Rough-in inspection for (3) new outlets on (2) newly exposed existing walls in dining / living rooms. Thank you! Phone #: ###-#### Inspection requested via web by Adam Staigle Areas noted and 1 additional receptacle added in hall as well. Rough in ok cover
|
ELE18-03469
| Final | 11/29/2018 | 11/29/2018 | 11/29/2018 11:28:00 AM | A | PASS |
|
|
code 4224 Phone #: ###-#### Inspection requested via web by Bob Glenn Final ok
|
ELE18-04534
| Electrical Rough-In | 11/28/2018 | 11/29/2018 | 11/29/2018 11:03:42 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Mark M Hardlids not ready, walls only rough in ok cover
|
ELE18-04536
| Electrical Rough-In | 11/28/2018 | 11/29/2018 | 11/29/2018 11:02:37 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Mark M Under slab for low voltage control cords for equipment rough in ok cover
|
ELE18-03297
| Final | 11/28/2018 | 11/29/2018 | 11/29/2018 11:01:14 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Mark M Final ok
|
ELE18-03827
| Final | 11/28/2018 | 11/29/2018 | 11/29/2018 8:52:19 AM | A | PASS |
|
|
garage code 2468 Phone #: ###-#### Inspection requested via web by Darryn Coburn Final ok
|