ELE08-01924
| Final | 11/2/2008 | 11/3/2008 | 11/3/2008 3:41:49 PM | P | FAIL |
|
|
Internet Inspection Request from: sam petterson corr, called BCC, and 410,2 & 16 install closet fixture, 210.70(A)(2) shall provide 3way or automatic switching for stairs to basement
|
ELE08-01787
| Final | 10/31/2008 | 11/3/2008 | 11/3/2008 2:28:45 PM | P | FAIL |
|
|
kyle Phone #: ###-#### 200.6&7 shall not use ungrounded conductor in MC cable as neutral, correction posted on BLD permit no violation to be retained 410.62(C) cord fed fixtures shall be fed with recept and cord cap or use factory canopy old work done without permit or inspection
|
ELE08-02847
| Electrical Rough-In | 11/3/2008 | 11/3/2008 | 11/3/2008 12:59:27 PM | P | PASS |
|
|
ceiling rough-in. Please call 1/2 hour prior to inspection so that I can be sure I will be on site to show the areas that need to be inspected. Thank you, Dan Phone #: ###-#### Internet Inspection Request from: Dan Wright r/i for fished cables in walls and wiring in ceilings ok for both rooms
|
ELE08-00296
| Electrical Rough-In | 11/1/2008 | 11/3/2008 | 11/3/2008 10:15:34 AM | A | PART |
|
|
ceiling inspection for cover Phone #: ###-#### Internet Inspection Request from: Karl Paige r/i ok anop
|
ESC06-00677
| Aging Inspection | 11/3/2008 | 11/3/2008 | 11/3/2008 9:47:12 AM | | DONE |
|
|
see added site final
|
ESC06-00677
| Site Final | 11/3/2008 | 11/3/2008 | 11/3/2008 9:46:49 AM | A | PASS |
|
|
note job was done on a W Rifleman address
|
ELE08-01522
| Conference | 11/3/2008 | 11/3/2008 | 11/3/2008 9:43:01 AM | A | DONE |
|
|
called contr will check on job and call for final
|
ELE08-01809
| Final | 10/31/2008 | 11/3/2008 | 11/3/2008 9:22:50 AM | A | PASS |
|
|
Kathy - ###-#### please call 30 min prior to arrange for access ok
|
ELE08-02670
| Final | 10/31/2008 | 11/3/2008 | 11/3/2008 8:37:57 AM | A | PASS |
|
|
Phone #: ###-#### ok
|
ESC08-00647
| General Inspection | 11/3/2008 | 11/3/2008 | 11/3/2008 8:37:36 AM | A | PASS |
|
|
site ok still needs landscaping east side , and back
|