Inspections for the day of: Tuesday, November 3, 2009.
Number of inspections: 18
Percentage of inspections complete: 94 %
Percentage of inspections not complete: 6 %
Contact Information
InspectorDoug A Poedy
TitleELE-INSPECTOR
Phone #447-7209
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC09-00670 Site Preparation10/28/200910/28/2009   
ELE09-02002 Electrical Rough-In11/2/200911/3/200911/3/2009 3:21:41 PMAFAIL
NEC 300.14 LENGTH OF FREE CONDUCTORS. NEC 314.29 CONDUIT BODIES TO BE ACCESSIBLE. NEC 210.4 B DICONNECTING MEANS FOR MULTI BRANCH CIRCUIITS.
ELE09-01751 Electrical Rough-In11/3/200911/3/200911/3/2009 2:58:26 PMPPASS
Sam Peterson Phone #: ###-####. Ok to cover addition.
ELE09-01675 Conference11/3/200911/3/200911/3/2009 2:57:14 PMPCANC
duplicate
ELE09-01393 Final11/3/200911/3/200911/3/2009 12:48:47 PMPPASS
Phone #: ###-#### Internet Inspection Request from: John McCurdy. Ok final.
ELE09-01393 DOC - Permit Finaled11/3/200911/3/200911/3/2009 12:48:25 PMPPASS
ELE09-01712 Final11/3/200911/3/200911/3/2009 12:22:03 PMPPASS
TERRY PLEASE CALL 10 MIN BEFORE GOING OUT THANKS Phone #: ###-####
ELE09-01949 Final11/3/200911/3/200911/3/2009 12:17:13 PMPPASS
Phone #: ###-#### Internet Inspection Request from: Clint Tate. NEC 422.51 Cord and plug connected vending machines. NEC210.8 b2 Commercial kitchens shall be gfci protected. Left survey and contacted contractor.
ELE09-01590 Final11/3/200911/3/200911/3/2009 11:21:13 AMAPASS
Desk ###-####
Cell ###-#### Phone #: ###-#### Internet Inspection Request from: mark morris
ELE09-01590 DOC - Permit Finaled11/3/200911/3/200911/3/2009 11:21:02 AMPPASS
GCE09-00034 GCE-Rough-In11/2/200911/3/200911/3/2009 11:20:35 AMACANC
Contact Brian@###-####. duplicate.
GCE09-00034 GCE-Rough-In11/2/200911/3/200911/3/2009 11:16:14 AMAPASS
Contact Brian@###-####. RIC ok
GCE09-00032 GCE-Final11/2/200911/3/200911/3/2009 11:07:49 AMACANC
Contact MIKE@ ###-####, Please call prior to come in for inspection.. Duplicate.
GCE09-00032 GCE-Final11/2/200911/3/200911/3/2009 11:07:20 AMAPASS
Contact MIKE@ ###-####, Please call prior to come in for inspection.. P/S O/H Reconnect ok.
ELE09-01989 Electrical Rough-In11/2/200911/3/200911/3/2009 9:42:32 AMAPASS
pat Phone #: ###-#### RIC OK
ELE09-01989 Permanent Service11/3/200911/3/200911/3/2009 9:42:07 AMAPASS
P/S U/G Connect ok.
ESC09-00432 General Inspection11/3/200911/3/200911/3/2009 9:22:03 AMAPASS
Looks good.
ELE09-02002 Electrical Rough-In11/2/200911/3/200911/2/2009 10:28:32 AMACANC
duplicate