ELE05-03507
| Final | 11/30/2005 | 11/30/2005 | 11/30/2005 4:08:12 PM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 11/30/2005 at 7:52:39 AM. Contact: ###-####. ok
|
ELE05-03297
| Final | 11/29/2005 | 11/30/2005 | 11/30/2005 3:18:46 PM | P | PASS |
|
|
Will be ready for final in the afternoon wednesday.; Phone #: ###-#### Internet Inspection Request from: Steve Syltie ok card signed
|
ELE05-04302
| Rough-In Permanent Service | 11/30/2005 | 11/30/2005 | 11/30/2005 2:23:34 PM | P | FAIL |
|
|
###-#### cor. met contractor, 300.10 needs bond bushing for RE washers, 310.15 derate wires in emt,250.104 bond hot and cold, 110.12 seal KOs, 358.42&314.15(A) use r/t fittings that are listed for wet location,312.5 needs conn for GEC at service, remove GEC from old panel (j box)
|
ELE05-04303
| Permanent Service | 11/30/2005 | 11/30/2005 | 11/30/2005 12:34:44 PM | P | CANC |
|
|
Scheduled by a contractor via Hello! on 11/30/2005 at 8:58:39 AM. Contact: ###-####. see added t/s , this is a t/s not p/s
|
ELE04-03054
| Electrical Rough-In | 11/29/2005 | 11/30/2005 | 11/30/2005 11:36:30 AM | A | PASS |
|
|
REINSPECT POOL BONDING PLEASE; Phone #: ###-#### Internet Inspection Request from: Barry Kendall equipopential grid ok
|
ELE05-04302
| Final | 11/29/2005 | 11/30/2005 | 11/30/2005 10:23:30 AM | A | NH |
|
|
###-#### - twin city no access called and this is a r/i/p/s not final contractor will reschedule and call me also needs to check grounding,is u/g water pipe
|
ELE05-03486
| Final | 11/29/2005 | 11/30/2005 | 11/30/2005 10:03:00 AM | A | NH |
|
|
final on kitchen & bath remodel and service upgrade. george cell # ###-#### Internet Inspection Request from: Andy Rose notice posted called left # page
|
ELE05-04048
| Final | 11/29/2005 | 11/30/2005 | 11/30/2005 9:07:49 AM | A | NR |
|
|
final on swimming pool Internet Inspection Request from: Andy Rose called
|
ELE05-03286
| Final | 11/29/2005 | 11/30/2005 | 11/30/2005 8:48:44 AM | A | NH |
|
|
Phone #: ###-#### Internet Inspection Request from: Joe Thomas notice posted called
|
ELE05-04293
| Electrical Rough-In | 11/29/2005 | 11/30/2005 | 11/30/2005 8:20:29 AM | A | PART |
|
|
###-#### - jim Note: underground for post line ok
|
ELE05-04292
| Temporary Service | 11/29/2005 | 11/30/2005 | 11/30/2005 8:05:48 AM | A | PASS |
|
|
###-#### - jim was done on pm#ele05-04153 p/s u/g new ok
|
ELE05-04303
| Temporary Service | 11/30/2005 | 11/30/2005 | 11/30/2005 12:00:00 AM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 11/30/2005 at 8:58:39 AM. Contact: ###-####. t/s o/h new ok
|