ESC09-00703
| General Inspection | 11/30/2009 | 11/30/2009 | 11/30/2009 4:07:37 PM | P | PASS |
|
|
looked ok
|
ESC09-00360
| General Inspection | 11/30/2009 | 11/30/2009 | 11/30/2009 4:06:42 PM | P | PASS |
|
|
looked ok
|
ESC09-00021
| General Inspection | 11/30/2009 | 11/30/2009 | 11/30/2009 4:06:05 PM | P | PASS |
|
|
looked ok
|
ELE09-02309
| Temporary Service | 11/30/2009 | 11/30/2009 | 11/30/2009 4:03:35 PM | P | PASS |
|
|
Neil Phone #: ###-#### t/s u/g n ok, no esc this project
|
ELE09-02305
| Permanent Service | 11/30/2009 | 11/30/2009 | 11/30/2009 4:02:05 PM | P | FAIL |
|
|
Robert Phone #: ###-#### called, left correction notice, NEC 312.5, 550.10(B) all conductors entering enclosure shall have abrasion protection, 240.5 ampacity of cord and receptacle shall be protected per table 400.5, 550.10(D) cord length shall be betwee 21' and 361/2', 550.10(G) cord shall be protected thru wall and floor, 110.12(A) shall close openings in mast weatherhead,110.3(A) ,110.20 outdoor enclosure shall be weather proof, 110.13 equipment shall be securely mounted and connections properly installed- cord connectors, no esc this project
|
ELE09-02308
| Temporary Service | 11/30/2009 | 11/30/2009 | 11/30/2009 3:08:24 PM | P | PASS |
|
|
Please see our Wireman on site Pat Thomas at ###-####. Thank you. Phone #: ###-#### Internet Inspection Request from: Clint Tate called, t/s o/h n ok, no esc this project
|
ELE09-02298
| Permanent Service | 11/30/2009 | 11/30/2009 | 11/30/2009 2:06:11 PM | P | CANC |
|
|
Please call me when you are on your way so i can meet you there. Thanks Dave ###-#### Phone #: ###-#### Internet Inspection Request from: jason shifflett wrong type request, see ri
|
ELE09-02298
| Electrical Rough-In | 11/30/2009 | 11/30/2009 | 11/30/2009 2:05:52 PM | P | PASS |
|
|
Please call me when you are on your way so i can meet you there. Thanks Dave ###-#### Phone #: ###-#### Internet Inspection Request from: jason shifflett ok to pour concrete encased electrode
|
ELE09-02004
| Permanent Service | 11/29/2009 | 11/30/2009 | 11/30/2009 1:04:25 PM | P | PASS |
|
|
idaho power will be disconnecting service at 9:00am if you could come around 1:00pm that would be great, thanks! Phone #: ###-#### Internet Inspection Request from: Chris Burke told electrician to call in for final service inspection to see j-box ,water pipe ground, rods, sub-panel to j-box, p/s u/g n ok, no esc this project
|
ELE09-02254
| Electrical Rough-In | 11/30/2009 | 11/30/2009 | 11/30/2009 12:21:39 PM | P | PART |
|
|
Underground Rough-in Phone #: ###-#### Internet Inspection Request from: Bryan Atkins ok to cover u/g anop, north part only
|
ELE09-01795
| Final | 11/25/2009 | 11/30/2009 | 11/30/2009 10:43:33 AM | A | PASS |
|
|
Please call Steve if locked for code info. Phone #: ###-#### Internet Inspection Request from: Barbara Szurgot ok to final, no card on site to sign, told owners would have to do electronically only
|
ELE09-02282
| Rough-In Permanent Service | 11/25/2009 | 11/30/2009 | 11/30/2009 9:47:45 AM | A | CANC |
|
|
Steve Phone #: ###-#### wrong type request see ri, no esc this project
|
ELE09-02282
| Electrical Rough-In | 11/30/2009 | 11/30/2009 | 11/30/2009 9:31:33 AM | A | PASS |
|
|
Steve Phone #: ###-#### ric ok 4 offices walls and ceilings, no esc this project
|
ELE09-01152
| Electrical Rough-In | 11/30/2009 | 11/30/2009 | 11/30/2009 9:29:15 AM | A | PASS |
|
|
Rough walls for control room & kitchen wall Phone #: ###-#### Internet Inspection Request from: Ron Zimmerman walls only ok to cover anop
|
ELE09-00957
| Electrical Rough-In | 11/25/2009 | 11/30/2009 | 11/30/2009 8:17:50 AM | A | PASS |
|
|
CONTACT: GARRETT COLLINS Phone #: ###-#### Internet Inspection Request from: Deb Gooden walls only ok to cover anop, no esc this project
|