ELE12-02890
| Temporary Service | 11/29/2012 | 11/30/2012 | 11/30/2012 3:33:59 PM | P | CANC |
|
|
IPCo will turn power off at 2:00pm, electrician will raise serv mast additional 3'' to clear trusses, elect inspect to then take place and IPCo will reconnect power to customer Phone #: ###-#### >> Inspection requested via web by joel smith called, talked to owner contractor, said to call for inspection after decide to raise mast, provide temp pole, or set new service panel, told electrical contractor to look at job before decide best way to go
|
ELE12-02635
| Permanent Service | 11/30/2012 | 11/30/2012 | 11/30/2012 12:26:19 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Lee VanSchoiack p/s, exst meter pak, n, ok
|
ELE12-02635
| Electrical Rough-In | 11/30/2012 | 11/30/2012 | 11/30/2012 12:25:21 PM | P | PASS |
|
|
grid ceiling Phone #: ###-#### >> Inspection requested via web by Lee VanSchoiack ri ok, ceiling cover
|
ELE12-02883
| Final | 11/30/2012 | 11/30/2012 | 11/30/2012 10:21:03 AM | A | PASS |
|
|
Contact: Greg Oyama Phone #: ###-#### >> Inspection requested via web by Deb Gooden ok final, no card
|
ELE12-02526
| Final | 11/29/2012 | 11/30/2012 | 11/30/2012 9:36:30 AM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by daniel bibikov ok final, signed card
|
ELE12-02477
| Final | 11/29/2012 | 11/30/2012 | 11/30/2012 8:24:31 AM | A | FAIL |
|
|
code 6012 Phone #: ###-#### >> Inspection requested via web by Neal Rumsey called, shall use listed box extenders per NEC 314 .20, shall secure nm cable within 12" of box, shall provide gfci protection in shed
|