Inspections for the day of: Friday, November 4, 2011.
Number of inspections: 5
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMike Jordan
TitleBLD-COM/RES INSPECTOR
Phone #794-9473
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC11-00564 Aging Inspection11/4/201111/4/201111/8/2011 12:41:27 PM DONE
GCB11-00041 GCB-Framing11/3/201111/4/201111/7/2011 8:17:41 AMACANC
DHA
BLD11-02344 BLD-Framing/Rough-in11/3/201111/4/201111/4/2011 3:35:34 PMPPASS
jake Phone #: ###-####
ESC11-00699 General Inspection11/4/201111/4/201111/4/2011 3:35:26 PMPPASS
BLD11-01802 BLD-Foundation11/3/201111/4/201111/4/2011 10:03:48 AMAFAIL
bob Phone #: ###-#### Approved plans call for special inspection for masonry, concrete and steel. Cleanouts are required for grout lifts exceeding 5ft. in height, Also clean out all mortar fins. Noted that p[lans show to grout solid only cells with reinforcement, no grout stop in wall was noted, Needs to check with engineer to ensure that steel beam will hold the additional weight of the grout. Correction notice posted, also spoke to project super about corrections.