Inspections for the day of: Monday, November 4, 2019.
Number of inspections: 20
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrian Scoles
TitleMEC INSPECTOR
Phone #914-4915
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC19-03932 Final11/4/201911/4/201911/4/2019 3:33:02 PMPPASS
Joe Phone #: ###-####- final ok- locking caps installed
MEC19-03390 Final11/4/201911/4/201911/4/2019 3:20:41 PMPPASS
call for access code // Joe Phone #: ###-####- final ok- locking caps installed
MEC19-03319 Final11/4/201911/4/201911/4/2019 3:10:14 PMPPASS
call for access code // Joe Phone #: ###-####- final ok- locking caps installed
MEC19-04966 Final11/4/201911/4/201911/4/2019 2:40:47 PMPPASS
kim Phone #: ###-####- furnace coil only co ok
MEC19-04625 Final11/4/201911/4/201911/4/2019 2:04:16 PMPNR
Please call me at ###-#### to insure access. Phone #: ###-#### Inspection requested via web by terry Warden- need 6" clearance from pvc to water heater flue and water flue supported with grade- need to finish all arma flex-
MEC19-04824 Final11/1/201911/4/201911/4/2019 1:30:03 PMPPASS
Dave ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks- furnace duct work coil dryer exhaust co ok- no gas piping under this permit was under water heater- no a/c either existing
MEC19-04833 Rough-in11/1/201911/4/201911/4/2019 12:22:41 PMPPASS
Phone #: ###-#### Inspection requested via web by Gary Reeves- R/I ok- need to seal main R/A can spot welds by final
MEC19-04833 Pressure Test11/1/201911/4/201911/4/2019 12:21:37 PMPCANC
Phone #: ###-#### Inspection requested via web by Gary Reeves- 20lb gas pass tagged meter location- 5lb flue pass
MEC19-02591 Rough-in11/2/201911/4/201911/4/2019 11:09:18 AMAPASS
ceiling cover for grid ceiling Phone #: ###-#### Inspection requested via web by Robin Cox- R/I ok on ceiling grid all areas ok for ceiling tiles-
MEC19-03621 Final11/1/201911/4/201911/4/2019 10:37:01 AMAPASS
Anthony ###-####
remote ; manual in pantry
code: 4141 Phone #: ###-#### Inspection requested via web by Mike Almanza- fireplace final ok
MEC19-01484 Final11/4/201911/4/201911/4/2019 10:31:53 AMAPASS
final ok
MEC19-04830 Final11/1/201911/4/201911/4/2019 10:12:16 AMACANC
Call ahead to Holly @ ###-#### when you are headed out. Phone #: ###-#### Inspection requested via web by Sarah Small- per phone call with homeowner scheduled for wrong day supposed to be next monday- is there gas test for this install
MEC19-04943 Pressure Test11/1/201911/4/201911/4/2019 10:06:53 AMAFAIL
Ricks Phone #: ###-####
1- gas test passed tagged meter location-
2- IRC 2406.2 prohibited locations appliance in bedroom shall have solid weater stripped door with self closing hinge and combustion air from outside
3- b vent needs 1 inch clearance to sheet rock and trim ring installed
4- need sediment trap installed between gas shut off and appliance and new appliance installed
5- plumbing permit needs reopened and inspection called in
MEC19-04692 Final10/31/201911/4/201911/4/2019 9:32:12 AMAFAIL
Phone #: ###-#### Inspection requested via web by Denise Colin- furnace a/c coil co locking caps ok- need electrical permit issued for electric to gas conversion and shutoff switch install at furnace
MEC19-04692 Pressure Test10/31/201911/4/201911/4/2019 9:29:16 AMAPASS
flue pressure test Phone #: ###-#### Inspection requested via web by Denise Colin- 5lb flue pass
MEC19-04895 Final10/29/201911/4/201911/4/2019 8:54:30 AMAPASS
PLEASE CALL HOMEOWNER BRETT WHEN 30 MINS IN ROUTE. FINAL FOR PLUMBING PERMIT SET FOR SAME DAY AND TIME FRAME. Phone #: ###-#### Inspection requested via web by Rick Montgomery- furnae a/c coil co locking caps ok
MEC19-03852 Final11/4/201911/4/201911/4/2019 8:36:30 AMAPASS
Jake is the contact. Phone #: ###-#### Inspection requested via web by stan lillquist- final ok
MEC19-04921 Final11/2/201911/4/201911/4/2019 8:21:02 AMAPASS
Please call before arrival for access info. Thank you ###-#### Phone #: ###-#### Inspection requested via web by Bruce Lacy- furnace a/c coil co locking caps ok
MEC15-02333 Mec-Aging Inspection11/4/201911/4/201911/4/2019 7:53:15 AM CANC
MEC15-02333 DOC - Permit Expired11/4/201911/4/201911/4/2019 7:53:03 AMAPASS
no calls- no activity- permit expired--