Inspections for the day of: Wednesday, November 5, 2008.
Number of inspections: 17
Percentage of inspections complete: 94 %
Percentage of inspections not complete: 6 %
Contact Information
InspectorMike Kinnear
TitleELE-INSPECTOR
Phone #794-1379
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE07-02895 Conference11/3/200811/4/2008 P 
phil ###-####
ELE08-02961 Rough-In Permanent Service11/4/200811/5/200811/5/2008 4:35:40 PMPPASS
Phone #: ###-#### Internet Inspection Request from: Dan Surerus ok cover ri note t/w dan regard bedrm door they need to make sure of the opening for wall spacing 6ft from opening p/s u/g reconnect ok
ESC08-00784 General Inspection11/5/200811/5/200811/5/2008 4:33:07 PMPPASS
sign posted site looks fine
ELE08-02963 Rough-In Permanent Service11/5/200811/5/200811/5/2008 3:45:56 PMPPASS
john Phone #: ###-#### ok cover ri notet/w john survey outlet needed by stairway in kitchen p/s u/g reconnect ok
ESC08-00935 General Inspection11/5/200811/5/200811/5/2008 3:43:34 PMPPASS
sign posted site looks fine
ESC08-00722 General Inspection11/5/200811/5/200811/5/2008 3:42:54 PMPPART
sign not posted called rp he would put it back up site looks fine
ELE08-02955 Conference11/4/200811/5/200811/5/2008 3:40:32 PMPDONE
quentin- call 1st before insp Phone #: ###-#### did phone conf. he needs to have the framing completed & then call for conf.
ESC08-00004 General Inspection11/5/200811/5/200811/5/2008 3:36:43 PMPPART
sign posted t/w rp road needs to sweep clean which they started before i left
ELE08-02957 Electrical Rough-In11/4/200811/5/200811/5/2008 3:34:17 PMAPASS
cal Phone #: ###-#### ok cover ri note service grounding not correct. t/w cal the griunding electrode conductors shall be continues from electrode to each panel.
ELE08-02765 Final11/4/200811/5/200811/5/2008 1:08:14 PMAPART
Final is for Unit 1312. See discription notes. Jim is the contact his no. is ###-####. Thank you. Phone #: ###-#### Internet Inspection Request from: Shawna Gates ok final for unit 1312 note no esc permit in priject
ELE08-02536 Electrical Rough-In11/4/200811/5/200811/5/2008 12:09:27 PMAPART
Requesting an inspection of slab work. Our man Scott will be there. Phone #: ###-#### Internet Inspection Request from: Dan Hardisty ok cover under ground conduit & boxes anop
ELE08-02956 Final11/4/200811/5/200811/5/2008 12:08:15 PMAPASS
Need a final electrical inspection, please call Clayton @ ###-#### if you have any questions. Phone #: ###-#### Internet Inspection Request from: Alison Pennington ok final
ELE08-02958 Permanent Service11/4/200811/5/200811/5/2008 12:07:02 PMANR
terry Phone #: ###-#### t/w terry he needs 2inch imc or rigid conduit for mast, ground metal water grounding electrode 5ft building entery, bond hot water pipe, panel blanks sub panel, plastic romex connector or approved ground choke for ground wires
ESC08-00935 General Inspection11/5/200811/5/200811/5/2008 12:01:02 PMAPASS
sign posted site looks fine
ESC08-00457 General Inspection11/5/200811/5/200811/5/2008 12:00:00 PMAPASS
sign posted site looks fine
ELE08-02840 Electrical Rough-In11/5/200811/5/200811/5/2008 11:56:26 AMAPASS
Ron Holbrook - Journeyman on the Jobsite Phone #: ###-#### Internet Inspection Request from: chris green ok cover ri note no esc permit in prpject
ESC07-01460 General Inspection11/5/200811/5/200811/5/2008 8:43:56 AMAPASS
sign posted site looks fine no landscape started